{"title":"Pool Heater Not Working: Igniters, Sensors, Switches \u0026 Control Boards","description":"\u003cp\u003eWhen a gas heater will not fire or shuts down, the usual culprits are the igniter, flame sensor, water or air pressure switch, thermistor, high limit or gas valve. Grouped by brand: Hayward H-Series, Jandy JXi \/ LXi \/ JXiQ, Pentair MasterTemp \/ Max-E-Therm \/ ETi, and Raypak Digital \/ Avia \/ Low NOx, plus Swimables aftermarket equivalents.\u003c\/p\u003e","products":[{"product_id":"hayward-integrated-control-board-for-h-series-heater","title":"Hayward IDXL2ICB1931 Integrated Control Board | For H-Series Heater","description":"\u003cp data-start=\"1463\" data-end=\"2047\" class=\"\"\u003eOEM Hayward IDXL2ICB1931 Integrated Control Board is an authentic replacement part for select Hayward H-Series Low NOx pool heaters. Designed for models H250IDL2, H350IDL2, and H400IDL2 manufactured after September 20, 2004, this board combines multiple functions—ignition sequencing, temperature control, and system diagnostics—into one compact unit. It includes three amp-style female connectors (1-4 pin, 1-3 pin, and 1-2 pin) for simple integration. As a genuine Hayward component, it helps restore reliable heating performance and supports the long-term operation of your system.\u003c\/p\u003e\n\u003ch3 data-start=\"2049\" data-end=\"2065\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2066\" data-end=\"2653\"\u003e\n\u003cli data-start=\"2066\" data-end=\"2188\" class=\"\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2188\" class=\"\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2103\"\u003eFor Post-2004 H-Series Heaters:\u003c\/strong\u003e Tailored to fit models H250IDL2, H350IDL2, and H400IDL2 built after Sept. 20, 2004\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2189\" data-end=\"2295\" class=\"\"\u003e\n\u003cp data-start=\"2191\" data-end=\"2295\" class=\"\"\u003e\u003cstrong data-start=\"2191\" data-end=\"2220\"\u003eAll-in-One Control Board:\u003c\/strong\u003e Manages ignition, temp settings, and diagnostics from a single interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2296\" data-end=\"2411\" class=\"\"\u003e\n\u003cp data-start=\"2298\" data-end=\"2411\" class=\"\"\u003e\u003cstrong data-start=\"2298\" data-end=\"2322\"\u003eOEM Fit and Quality:\u003c\/strong\u003e Manufactured to Hayward specifications for dependable performance and system longevity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2412\" data-end=\"2520\" class=\"\"\u003e\n\u003cp data-start=\"2414\" data-end=\"2520\" class=\"\"\u003e\u003cstrong data-start=\"2414\" data-end=\"2441\"\u003eSimple Connector Setup:\u003c\/strong\u003e Features three amp-style plugs to match existing wiring without modification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2521\" data-end=\"2653\" class=\"\"\u003e\n\u003cp data-start=\"2523\" data-end=\"2653\" class=\"\"\u003e\u003cstrong data-start=\"2523\" data-end=\"2555\"\u003eRestores Reliable Operation:\u003c\/strong\u003e Replaces faulty boards to ensure accurate heating, safety checks, and water temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eHayward IDXL2ICB1931 Control Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward Universal H-Series Low NOx Induced Draft Heater Models:\u003c\/strong\u003e H250IDL2, H350IDL2, and H400IDL2 (Manufactured after September 20, 2004)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1292\" data-end=\"1311\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1313\" data-end=\"1369\" class=\"\"\u003eHayward Replacement Board for Induced Draft Heaters\u003c\/h2\u003e\n\u003ch4 data-start=\"1370\" data-end=\"1434\" class=\"\"\u003ebuy idxl2icb1931 board locally for hayward low nox heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1435\" data-end=\"1489\" class=\"\"\u003ewhere to get hayward idxl2icb1931 control board\u003c\/h4\u003e\n\u003ch4 data-start=\"1490\" data-end=\"1549\" class=\"\"\u003eidxl2icb1931 compatible with h-series digital models\u003c\/h4\u003e\n\u003ch4 data-start=\"1550\" data-end=\"1611\" class=\"\"\u003efix no ignition on h350idl2 with hayward control board\u003c\/h4\u003e\n\u003ch4 data-start=\"1612\" data-end=\"1662\" class=\"\"\u003elocal pricing on hayward idxl2icb1931 board\u003c\/h4\u003e\n\u003ch2 data-start=\"1664\" data-end=\"1719\" class=\"\"\u003eFixing Heater Control Problems and Ignition Issues\u003c\/h2\u003e\n\u003ch4 data-start=\"1720\" data-end=\"1777\" class=\"\"\u003eignition module failure hayward heater won’t start\u003c\/h4\u003e\n\u003ch4 data-start=\"1778\" data-end=\"1833\" class=\"\"\u003edigital display not working replace idxl2icb1931\u003c\/h4\u003e\n\u003ch4 data-start=\"1834\" data-end=\"1890\" class=\"\"\u003estuck relay on heater board replace with oem part\u003c\/h4\u003e\n\u003ch4 data-start=\"1891\" data-end=\"1949\" class=\"\"\u003ehayward heater keeps shutting off new control board\u003c\/h4\u003e\n\u003ch4 data-start=\"1950\" data-end=\"2010\" class=\"\"\u003etemperature sensor not responding change idxl2icb1931\u003c\/h4\u003e\n\u003ch2 data-start=\"2012\" data-end=\"2043\" class=\"\"\u003eSetup and Connection Guide\u003c\/h2\u003e\n\u003ch4 data-start=\"2044\" data-end=\"2101\" class=\"\"\u003eidxl2icb1931 board with amp-style plug connections\u003c\/h4\u003e\n\u003ch4 data-start=\"2102\" data-end=\"2154\" class=\"\"\u003ewhich control board fits h400idl2 pool heater\u003c\/h4\u003e\n\u003ch4 data-start=\"2155\" data-end=\"2214\" class=\"\"\u003ehow to identify right replacement board for h-series\u003c\/h4\u003e\n\u003ch4 data-start=\"2215\" data-end=\"2275\" class=\"\"\u003edoes idxl2icb1931 work with natural gas heater models\u003c\/h4\u003e\n\u003ch4 data-start=\"2276\" data-end=\"2334\" class=\"\"\u003eunion install tip for hayward induced draft systems\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597178081571,"sku":"IDXL2ICB1931","price":318.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/HaywardIntegratedControlBoardForH-SeriesHeaterIDXL2ICB1931WholesalePoolMart1.jpg?v=1736789583"},{"product_id":"jandy-ignition-control-for-jxi-and-lxi-heaters-r0456900","title":"Jandy R0456900 Ignition Control | JXi | LXi Heaters","description":"\u003cp\u003eOEM Jandy Ignition Control R0456900 is an essential hot surface ignition controller for JXi and LXi Low NOx gas heaters. It manages the timing and delivery of electrical signals to initiate gas ignition, helping the heater maintain reliable startup and consistent performance. Built to OEM standards, this module fits directly into compatible models without modification. Replacing a worn or faulty controller ensures proper heating operation and prevents ignition delays, contributing to safe, uninterrupted pool or spa temperature regulation over time.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1266\" data-end=\"1462\" class=\"\"\u003e\n\u003cp data-start=\"1268\" data-end=\"1462\" class=\"\"\u003e\u003cstrong data-start=\"1268\" data-end=\"1310\"\u003eManages Hot Surface Ignition Sequence:\u003c\/strong\u003e Regulates the timing and delivery of ignition signals to ensure precise gas ignition, supporting safe operation and dependable startup in gas heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1463\" data-end=\"1672\" class=\"\"\u003e\n\u003cp data-start=\"1465\" data-end=\"1672\" class=\"\"\u003e\u003cstrong data-start=\"1465\" data-end=\"1509\"\u003eTailored for JXi and LXi Low NOx Models:\u003c\/strong\u003e Manufactured specifically for compatibility with Jandy’s JXi and LXi heater lines, eliminating the guesswork in replacements and ensuring consistent integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1673\" data-end=\"1868\" class=\"\"\u003e\n\u003cp data-start=\"1675\" data-end=\"1868\" class=\"\"\u003e\u003cstrong data-start=\"1675\" data-end=\"1714\"\u003eSupports Consistent Heater Startup:\u003c\/strong\u003e Minimizes issues related to ignition lag or misfires by delivering steady signal control, preserving performance even in varying pool or spa conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1869\" data-end=\"2074\" class=\"\"\u003e\n\u003cp data-start=\"1871\" data-end=\"2074\" class=\"\"\u003e\u003cstrong data-start=\"1871\" data-end=\"1919\"\u003eEssential for Efficient Temperature Control:\u003c\/strong\u003e Keeps the heating process running smoothly by enabling uninterrupted ignition cycles, helping your system reach and maintain the set temperature quickly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2075\" data-end=\"2273\" class=\"\"\u003e\n\u003cp data-start=\"2077\" data-end=\"2273\" class=\"\"\u003e\u003cstrong data-start=\"2077\" data-end=\"2113\"\u003eTrusted OEM Performance and Fit:\u003c\/strong\u003e This genuine Jandy part is factory-tested for quality assurance, giving peace of mind that it will perform reliably and extend the life of your heater system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eJandy R0456900 Ignition Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eJandy LXi Heaters\u003c\/li\u003e\n\u003cli\u003eJandy JXi Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1663\" data-end=\"1682\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1684\" data-end=\"1758\" class=\"\"\u003eJXi and LXi Ignition Control R0456900 – Electrical Module For Startup\u003c\/h2\u003e\n\u003ch4 data-start=\"1759\" data-end=\"1833\" class=\"\"\u003eR0456900 controls electric signal to hot surface ignitor in JXi\/LXi\u003c\/h4\u003e\n\u003ch4 data-start=\"1834\" data-end=\"1903\" class=\"\"\u003eheater clicks but won’t ignite? R0456900 may resolve the issue\u003c\/h4\u003e\n\u003ch4 data-start=\"1904\" data-end=\"1973\" class=\"\"\u003eJandy R0456900 ensures flame ignition without delays or resets\u003c\/h4\u003e\n\u003ch4 data-start=\"1974\" data-end=\"2034\" class=\"\"\u003eOEM part fits JXi and LXi Low NOx natural gas heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"2035\" data-end=\"2109\" class=\"\"\u003elocal availability for ignition control board R0456900 replacements\u003c\/h4\u003e\n\u003ch2 data-start=\"2111\" data-end=\"2182\" class=\"\"\u003eJandy R0456900 Control Module – For Consistent Gas Heater Ignition\u003c\/h2\u003e\n\u003ch4 data-start=\"2183\" data-end=\"2250\" class=\"\"\u003efix failed burner ignition or startup lockouts with R0456900\u003c\/h4\u003e\n\u003ch4 data-start=\"2251\" data-end=\"2315\" class=\"\"\u003eR0456900 integrates with safety loop and startup sequence\u003c\/h4\u003e\n\u003ch4 data-start=\"2316\" data-end=\"2383\" class=\"\"\u003ereliable flame-up and error-free ignition with part R0456900\u003c\/h4\u003e\n\u003ch4 data-start=\"2384\" data-end=\"2446\" class=\"\"\u003ecompatible with all models of Jandy JXi and LXi heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"2447\" data-end=\"2511\" class=\"\"\u003eideal for pool\/spa techs servicing Jandy ignition systems\u003c\/h4\u003e\n\u003ch2 data-start=\"2513\" data-end=\"2579\" class=\"\"\u003eIgnition Board R0456900 – For Efficient Heater Flame Ignition\u003c\/h2\u003e\n\u003ch4 data-start=\"2580\" data-end=\"2648\" class=\"\"\u003eR0456900 part ensures heater lights on first cycle every time\u003c\/h4\u003e\n\u003ch4 data-start=\"2649\" data-end=\"2715\" class=\"\"\u003eOEM-grade ignition board helps avoid error codes and faults\u003c\/h4\u003e\n\u003ch4 data-start=\"2716\" data-end=\"2788\" class=\"\"\u003eincludes full ignition control module for JXi\/LXi system upgrades\u003c\/h4\u003e\n\u003ch4 data-start=\"2789\" data-end=\"2858\" class=\"\"\u003eR0456900 restores heater function after faulty control failure\u003c\/h4\u003e\n\u003ch4 data-start=\"2859\" data-end=\"2928\" class=\"\"\u003eprecision control of spark sequence with R0456900 installation\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50597867684131,"sku":"R0456900","price":379.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/JandyIgnitionControlForJXiandLXiHeatersR0456900WholesalePoolMart2.jpg?v=1741037786"},{"product_id":"jandy-hot-surface-ignitor-for-lxi-heaters-r0457500","title":"Jandy R0457500 Hot Surface Ignitor | LXi Heaters","description":"\u003cp data-start=\"1993\" data-end=\"2569\" class=\"\"\u003eOEM Jandy Hot Surface Ignitor R0457500 is a crucial component for Jandy LXi Low NOx gas heaters, designed to handle both ignition and flame detection in one compact unit. Made from high-performance silicon carbide, this glow bar ignitor delivers fast, consistent ignition when the system calls for heat. It also monitors flame presence to ensure safety throughout the heating cycle. Built for reliable long-term use, it installs easily as a direct-fit OEM replacement, restoring your heater’s performance and helping to maintain stable water temperatures without interruption.\u003c\/p\u003e\n\u003ch3 data-start=\"2571\" data-end=\"2585\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2587\" data-end=\"3412\"\u003e\n\u003cli data-start=\"2587\" data-end=\"2757\" class=\"\"\u003e\n\u003cp data-start=\"2589\" data-end=\"2757\" class=\"\"\u003e\u003cstrong data-start=\"2589\" data-end=\"2619\"\u003eFast and Reliable Startup:\u003c\/strong\u003e Generates high heat to ignite the burner whenever required, ensuring your heater responds promptly and performs consistently during use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2758\" data-end=\"2921\" class=\"\"\u003e\n\u003cp data-start=\"2760\" data-end=\"2921\" class=\"\"\u003e\u003cstrong data-start=\"2760\" data-end=\"2797\"\u003eFlame Detection for Added Safety:\u003c\/strong\u003e Functions as a flame sensor as well, helping the system detect and confirm combustion to avoid errors or unsafe shutdowns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2922\" data-end=\"3097\" class=\"\"\u003e\n\u003cp data-start=\"2924\" data-end=\"3097\" class=\"\"\u003e\u003cstrong data-start=\"2924\" data-end=\"2954\"\u003eLong-Lasting Construction:\u003c\/strong\u003e Manufactured using durable materials that withstand high temperatures and provide extended service life in challenging poolside environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3098\" data-end=\"3247\" class=\"\"\u003e\n\u003cp data-start=\"3100\" data-end=\"3247\" class=\"\"\u003e\u003cstrong data-start=\"3100\" data-end=\"3127\"\u003eOEM Replacement Design:\u003c\/strong\u003e Compatible with Jandy LXi Low NOx heaters, it replaces your original ignitor precisely with no modifications required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3248\" data-end=\"3412\" class=\"\"\u003e\n\u003cp data-start=\"3250\" data-end=\"3412\" class=\"\"\u003e\u003cstrong data-start=\"3250\" data-end=\"3285\"\u003ePromotes Stable Heating Cycles:\u003c\/strong\u003e Helps keep your heater running efficiently by regulating the ignition process and confirming safe flame operation every time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eIgnitor\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eInsulation Wrap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eBracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eNuts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eStar Washers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(15) \u003c\/strong\u003eScrews\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eJandy LXi Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1663\" data-end=\"1682\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1684\" data-end=\"1749\" class=\"\"\u003eLXi Heater Ignitor R0457500 – Safe Startup and Flame Sensing\u003c\/h2\u003e\n\u003ch4 data-start=\"1750\" data-end=\"1818\" class=\"\"\u003eJandy R0457500 ignitor and flame sensor combo for LXi heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1819\" data-end=\"1885\" class=\"\"\u003epart R0457500 lights burner reliably when heat is requested\u003c\/h4\u003e\n\u003ch4 data-start=\"1886\" data-end=\"1948\" class=\"\"\u003eincludes mounting bracket, wrap, nuts, and star washers\u003c\/h4\u003e\n\u003ch4 data-start=\"1949\" data-end=\"2015\" class=\"\"\u003eglow bar R0457500 helps prevent ignition failure or lockout\u003c\/h4\u003e\n\u003ch4 data-start=\"2016\" data-end=\"2079\" class=\"\"\u003elocal pricing available on Jandy heater ignitor R0457500\u003c\/h4\u003e\n\u003ch2 data-start=\"2081\" data-end=\"2156\" class=\"\"\u003eJandy R0457500 Ignitor – Dual-Function Replacement for Low NOx Heaters\u003c\/h2\u003e\n\u003ch4 data-start=\"2157\" data-end=\"2227\" class=\"\"\u003eR0457500 used for both igniting gas and confirming burner flame\u003c\/h4\u003e\n\u003ch4 data-start=\"2228\" data-end=\"2291\" class=\"\"\u003ehot surface ignitor R0457500 installs quickly and easily\u003c\/h4\u003e\n\u003ch4 data-start=\"2292\" data-end=\"2357\" class=\"\"\u003edurable silicon carbide element built for repeated cycling\u003c\/h4\u003e\n\u003ch4 data-start=\"2358\" data-end=\"2425\" class=\"\"\u003eR0457500 ideal for troubleshooting startup or flame dropouts\u003c\/h4\u003e\n\u003ch4 data-start=\"2426\" data-end=\"2494\" class=\"\"\u003ecomplete kit includes all needed hardware for secure mounting\u003c\/h4\u003e\n\u003ch2 data-start=\"2496\" data-end=\"2568\" class=\"\"\u003eIgnitor Kit R0457500 – For Jandy Pool \u0026amp; Spa Heater Ignition Systems\u003c\/h2\u003e\n\u003ch4 data-start=\"2569\" data-end=\"2637\" class=\"\"\u003epart R0457500 fits LXi models and ensures safe flame presence\u003c\/h4\u003e\n\u003ch4 data-start=\"2638\" data-end=\"2707\" class=\"\"\u003eR0457500 meets OEM specs for Jandy natural gas heater ignition\u003c\/h4\u003e\n\u003ch4 data-start=\"2708\" data-end=\"2774\" class=\"\"\u003ereplace old or brittle ignitors with updated R0457500 model\u003c\/h4\u003e\n\u003ch4 data-start=\"2775\" data-end=\"2842\" class=\"\"\u003edesigned for use in high-moisture and high-temp heater zones\u003c\/h4\u003e\n\u003ch4 data-start=\"2843\" data-end=\"2909\" class=\"\"\u003eR0457500 hot surface ignition keeps heater running smoothly\u003c\/h4\u003e\n\u003ch3\u003eDiagram\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Jandy Hot Surface Ignitor For LXi Heaters | R0457500\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Hot_Surface_Ignitor_For_LXi_Heaters_R0457500_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732650671\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50597869584675,"sku":"R0457500","price":128.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Hot_Surface_Ignitor_For_LXi_Heaters_R0457500_Wholesale_Pool_Mart_1.jpg?v=1741037723"},{"product_id":"jandy-flame-sensor-rod-for-lxi-heaters-r0458600","title":"Jandy R0458600 Flame Sensor Rod | LXi Heaters","description":"\u003cp data-start=\"1847\" data-end=\"2423\" class=\"\"\u003eOEM Jandy Flame Sensor Rod R0458600 ensures safe and efficient ignition for Jandy LXi pool and spa heaters by verifying flame presence during startup and operation. This sensor helps your system detect combustion activity in real time and halts operation if no flame is detected, preventing gas-related risks. It’s engineered for compatibility with LXi models and offers a direct replacement with no modifications needed. Routine replacement of this sensor not only prevents system malfunctions but also ensures uninterrupted heat delivery when your pool or spa needs it most.\u003c\/p\u003e\n\u003ch3 data-start=\"2425\" data-end=\"2439\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2441\" data-end=\"3215\"\u003e\n\u003cli data-start=\"2441\" data-end=\"2601\" class=\"\"\u003e\n\u003cp data-start=\"2443\" data-end=\"2601\" class=\"\"\u003e\u003cstrong data-start=\"2443\" data-end=\"2483\"\u003eValidates Flame Presence for Safety:\u003c\/strong\u003e Continuously checks for active flame to authorize gas flow and maintain secure operation of your pool or spa heater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2602\" data-end=\"2757\" class=\"\"\u003e\n\u003cp data-start=\"2604\" data-end=\"2757\" class=\"\"\u003e\u003cstrong data-start=\"2604\" data-end=\"2646\"\u003eProtects Against Hazardous Conditions:\u003c\/strong\u003e Initiates automatic shutdown when flame is absent, minimizing the chance of unsafe combustion or overheating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2758\" data-end=\"2912\" class=\"\"\u003e\n\u003cp data-start=\"2760\" data-end=\"2912\" class=\"\"\u003e\u003cstrong data-start=\"2760\" data-end=\"2799\"\u003eTailored Fit for Jandy LXi Heaters:\u003c\/strong\u003e Designed to integrate seamlessly into LXi heater models, providing OEM-grade performance and installation ease\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2913\" data-end=\"3055\" class=\"\"\u003e\n\u003cp data-start=\"2915\" data-end=\"3055\" class=\"\"\u003e\u003cstrong data-start=\"2915\" data-end=\"2953\"\u003eHelps Avoid Service Interruptions:\u003c\/strong\u003e Prevents ignition failure and unplanned outages when replaced proactively during maintenance cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3056\" data-end=\"3215\" class=\"\"\u003e\n\u003cp data-start=\"3058\" data-end=\"3215\" class=\"\"\u003e\u003cstrong data-start=\"3058\" data-end=\"3099\"\u003eBuilt for Harsh Heating Environments:\u003c\/strong\u003e Withstands exposure to high heat and moisture, delivering dependable performance in demanding poolside conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eFlame Sensor Rod\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eInsulation Wrap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(15) \u003c\/strong\u003eScrews\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJandy LXi Heater Models: \u003c\/strong\u003e\u003cspan\u003eLXI250N, LXI250NN, LXI400N, LXI400NN, LXI250NC, LXI250NS, LXI400NC, LXI400NS LXI250P, LXI250PN, LXI400P, LXI400PN, LXI250PC, LXI250PS, LXI400PC, LXI400PS\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1632\" data-end=\"1651\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1653\" data-end=\"1727\" class=\"\"\u003eLXi Heater Flame Rod R0458600 – Safety Sensor For Ignition Monitoring\u003c\/h2\u003e\n\u003ch4 data-start=\"1728\" data-end=\"1794\" class=\"\"\u003epart R0458600 used in flame detection circuit of LXi heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1795\" data-end=\"1862\" class=\"\"\u003efits models LXI250PN, LXI400PS, LXI250NS, LXI400NC, and more\u003c\/h4\u003e\n\u003ch4 data-start=\"1863\" data-end=\"1929\" class=\"\"\u003ereplace sensor if burner lights but system shuts down early\u003c\/h4\u003e\n\u003ch4 data-start=\"1930\" data-end=\"1991\" class=\"\"\u003eR0458600 helps maintain reliable pool heater operation\u003c\/h4\u003e\n\u003ch4 data-start=\"1992\" data-end=\"2061\" class=\"\"\u003elocal availability on Jandy flame sensor R0458600 replacements\u003c\/h4\u003e\n\u003ch2 data-start=\"2063\" data-end=\"2126\" class=\"\"\u003eJandy R0458600 Flame Sensor – Stops Gas Flow Without Flame\u003c\/h2\u003e\n\u003ch4 data-start=\"2127\" data-end=\"2200\" class=\"\"\u003esensor part R0458600 improves safety by confirming flame-on status\u003c\/h4\u003e\n\u003ch4 data-start=\"2201\" data-end=\"2271\" class=\"\"\u003eR0458600 keeps ignition loop stable and heater running smoothly\u003c\/h4\u003e\n\u003ch4 data-start=\"2272\" data-end=\"2336\" class=\"\"\u003ereplace worn or dirty flame rods with Jandy part R0458600\u003c\/h4\u003e\n\u003ch4 data-start=\"2337\" data-end=\"2407\" class=\"\"\u003ecompatible with all LXi natural gas and propane heater variants\u003c\/h4\u003e\n\u003ch4 data-start=\"2408\" data-end=\"2469\" class=\"\"\u003eincludes screws and wrap for easy bolt-in installation\u003c\/h4\u003e\n\u003ch2 data-start=\"2471\" data-end=\"2538\" class=\"\"\u003eIgnition Flame Sensor R0458600 – Reliable Burner Detection Rod\u003c\/h2\u003e\n\u003ch4 data-start=\"2539\" data-end=\"2605\" class=\"\"\u003ereplace broken flame probe with R0458600 in Jandy LXi units\u003c\/h4\u003e\n\u003ch4 data-start=\"2606\" data-end=\"2674\" class=\"\"\u003ecritical part for verifying safe combustion during heat cycle\u003c\/h4\u003e\n\u003ch4 data-start=\"2675\" data-end=\"2744\" class=\"\"\u003eR0458600 prevents risk of unlit gas flow or heater error codes\u003c\/h4\u003e\n\u003ch4 data-start=\"2745\" data-end=\"2810\" class=\"\"\u003eused by techs during startup faults and diagnostic repairs\u003c\/h4\u003e\n\u003ch4 data-start=\"2811\" data-end=\"2882\" class=\"\"\u003eOEM sensor ensures proper length, signal, and fit in burner tray\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan\u003eDiagram\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Jandy Flame Sensor Rod For LXi Heaters | R0458600\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Flame_Sensor_Rod_For_LXi_Heaters_R0458600_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732650523\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50597872402723,"sku":"R0458600","price":63.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Flame_Sensor_Rod_For_LXi_Heaters_R0458600_Wholesale_Pool_Mart_1.jpg?v=1741037637"},{"product_id":"jandy-capacitor-blower-for-jxi-heaters-r0614500","title":"Jandy R0614500 Capacitor Blower | JXI Heaters","description":"\u003cp data-start=\"1930\" data-end=\"2517\"\u003eOEM Jandy R0614500 Capacitor Blower is a factory component for JXi pool and spa heaters, built to support proper combustion and airflow. By supplying the blower motor with the electrical boost it needs to start and operate, this capacitor ensures heaters maintain consistent performance. A failing capacitor can result in reduced airflow, ignition delays, or system inefficiency, making replacement vital for long-term heater reliability. Built with durability in mind, the R0614500 provides dependable service and is compatible with a wide range of JXi natural gas and propane models.\u003c\/p\u003e\n\u003ch3 data-start=\"2519\" data-end=\"2535\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2537\" data-end=\"3171\"\u003e\n\u003cli data-start=\"2537\" data-end=\"2651\"\u003e\n\u003cp data-start=\"2539\" data-end=\"2651\"\u003e\u003cstrong data-start=\"2539\" data-end=\"2563\"\u003eOEM Jandy Component:\u003c\/strong\u003e Genuine R0614500 blower capacitor designed for JXi natural and propane heater models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2652\" data-end=\"2778\"\u003e\n\u003cp data-start=\"2654\" data-end=\"2778\"\u003e\u003cstrong data-start=\"2654\" data-end=\"2681\"\u003eEnsures Proper Airflow:\u003c\/strong\u003e Works with the blower motor to deliver the airflow required for safe and efficient combustion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2779\" data-end=\"2910\"\u003e\n\u003cp data-start=\"2781\" data-end=\"2910\"\u003e\u003cstrong data-start=\"2781\" data-end=\"2809\"\u003eReduces Heater Failures:\u003c\/strong\u003e Prevents issues such as poor ignition or airflow interruptions that can cause system inefficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2911\" data-end=\"3038\"\u003e\n\u003cp data-start=\"2913\" data-end=\"3038\"\u003e\u003cstrong data-start=\"2913\" data-end=\"2943\"\u003eReliable Electrical Boost:\u003c\/strong\u003e Provides stable power to the blower motor, ensuring smooth operation across repeated cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3039\" data-end=\"3171\"\u003e\n\u003cp data-start=\"3041\" data-end=\"3171\"\u003e\u003cstrong data-start=\"3041\" data-end=\"3071\"\u003eCritical Maintenance Part:\u003c\/strong\u003e Essential for keeping JXi heaters in safe working condition and supporting long-term performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eJandy JXi Heater Models: \u003c\/span\u003e\u003c\/strong\u003eJXI400N, JXI400NK, JXI400NN, JXI260N, JXI260NK, JXI200N, JXI200NK, JXI400NC, JXI260NC Natural and JXI400P, JXI400PN, JXI400PK, JXI260P, JXI260PK, JXI200P, JXI200PK, JXI400PC, JXI260PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1892\" data-end=\"1913\"\u003eAdditional Info\u003c\/h3\u003e\n\u003cp data-start=\"1914\" data-end=\"2113\"\u003eLooking for the Jandy R0614500 Capacitor Blower? This OEM replacement supports proper airflow and startup for JXi heater blower motors. Below are details on installation, safety, and local pricing.\u003c\/p\u003e\n\u003ch2 data-start=\"2115\" data-end=\"2154\"\u003eReplacing the JXi Blower Capacitor\u003c\/h2\u003e\n\u003cp data-start=\"2155\" data-end=\"2246\"\u003eThe capacitor provides the electrical boost needed to start and sustain blower operation.\u003c\/p\u003e\n\u003ch4 data-start=\"2248\" data-end=\"2329\"\u003eHow can I check local shop stock for the Jandy R0614500 capacitor near me?\u003c\/h4\u003e\n\u003ch4 data-start=\"2330\" data-end=\"2405\"\u003eDoes the capacitor install easily without rewiring the blower motor?\u003c\/h4\u003e\n\u003ch4 data-start=\"2406\" data-end=\"2483\"\u003eWhat’s the best way to secure the capacitor inside the heater cabinet?\u003c\/h4\u003e\n\u003ch4 data-start=\"2484\" data-end=\"2551\"\u003eDo local suppliers also carry blower motors for JXi heaters?\u003c\/h4\u003e\n\u003ch2 data-start=\"2553\" data-end=\"2595\"\u003eMaintaining Reliable Heater Operation\u003c\/h2\u003e\n\u003cp data-start=\"2596\" data-end=\"2685\"\u003eThis component ensures steady airflow for safe combustion and efficient heating cycles.\u003c\/p\u003e\n\u003ch4 data-start=\"2687\" data-end=\"2758\"\u003eWhy is the blower capacitor critical for JXi heater performance?\u003c\/h4\u003e\n\u003ch4 data-start=\"2759\" data-end=\"2822\"\u003eCan a weak capacitor cause airflow or ignition problems?\u003c\/h4\u003e\n\u003ch4 data-start=\"2823\" data-end=\"2892\"\u003eCan I compare local prices for the R0614500 before purchasing?\u003c\/h4\u003e\n\u003ch4 data-start=\"2893\" data-end=\"2965\"\u003eDoes replacing the capacitor help avoid premature blower failure?\u003c\/h4\u003e\n\u003ch2 data-start=\"2967\" data-end=\"3009\"\u003eLocal Compatibility and Fit Questions\u003c\/h2\u003e\n\u003cp data-start=\"3010\" data-end=\"3081\"\u003eThe R0614500 fits multiple natural gas and propane JXi heater models.\u003c\/p\u003e\n\u003ch4 data-start=\"3083\" data-end=\"3160\"\u003eWhich heater models confirm compatibility with the R0614500 capacitor?\u003c\/h4\u003e\n\u003ch4 data-start=\"3161\" data-end=\"3221\"\u003eCan I buy this capacitor at a local pool supply shop?\u003c\/h4\u003e\n\u003ch4 data-start=\"3222\" data-end=\"3285\"\u003eHow do local prices compare for Jandy blower capacitors?\u003c\/h4\u003e\n\u003ch4 data-start=\"3286\" data-end=\"3368\"\u003eDoes the capacitor work across both commercial and residential JXi heaters?\u003c\/h4\u003e\n\u003ch3\u003eDiagram\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Jandy Capacitor Blower For JXI Heaters | R0614500\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Capacitor_Blower_For_JXI_Heaters_R0614500_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732650474\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50597872599331,"sku":"R0614500","price":19.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Capacitor_Blower_For_JXI_Heaters_R0614500_Wholesale_Pool_Mart_1.jpg?v=1741037625"},{"product_id":"jandy-water-pressure-switch-for-lxi-heaters-r0457000","title":"Jandy R0457000 Pressure Switch | Water | LXi Heaters","description":"\u003cp data-start=\"1770\" data-end=\"2350\" class=\"\"\u003eOEM Jandy R0457000 Water Pressure Switch is a safety-critical component designed to regulate heater operation in Jandy LXi pool and spa models. This switch senses pressure levels in the plumbing system and disables the heater if water flow becomes insufficient, protecting internal parts from overheating. It is built to Jandy’s factory standards for precise performance and long-term use in demanding pool environments. A direct replacement for the original, this pressure switch is essential for maintaining heater safety, ensuring efficient function, and extending system life.\u003c\/p\u003e\n\u003ch3 data-start=\"2352\" data-end=\"2366\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2368\" data-end=\"3129\"\u003e\n\u003cli data-start=\"2368\" data-end=\"2516\" class=\"\"\u003e\n\u003cp data-start=\"2370\" data-end=\"2516\" class=\"\"\u003e\u003cstrong data-start=\"2370\" data-end=\"2415\"\u003eTriggers Heater Shutdown on Low Pressure:\u003c\/strong\u003e Detects when flow is inadequate and halts heater function to avoid heat exchanger or sensor damage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2517\" data-end=\"2677\" class=\"\"\u003e\n\u003cp data-start=\"2519\" data-end=\"2677\" class=\"\"\u003e\u003cstrong data-start=\"2519\" data-end=\"2562\"\u003eSupports Consistent Heating Efficiency:\u003c\/strong\u003e Ensures that the system heats only when proper flow is present, reducing cycling and wear on internal components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2678\" data-end=\"2811\" class=\"\"\u003e\n\u003cp data-start=\"2680\" data-end=\"2811\" class=\"\"\u003e\u003cstrong data-start=\"2680\" data-end=\"2716\"\u003eExact Fit for LXi Heater Models:\u003c\/strong\u003e Specifically designed for Jandy LXi systems, guaranteeing a quick, trouble-free installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2812\" data-end=\"2975\" class=\"\"\u003e\n\u003cp data-start=\"2814\" data-end=\"2975\" class=\"\"\u003e\u003cstrong data-start=\"2814\" data-end=\"2859\"\u003eBuilt to Withstand Harsh Pool Conditions:\u003c\/strong\u003e OEM-tested for long-lasting performance under temperature shifts, pressure fluctuations, and exposure to moisture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2976\" data-end=\"3129\" class=\"\"\u003e\n\u003cp data-start=\"2978\" data-end=\"3129\" class=\"\"\u003e\u003cstrong data-start=\"2978\" data-end=\"3019\"\u003eEssential for Preventive Maintenance:\u003c\/strong\u003e Replacing a faulty switch restores your heater’s safety mechanism, reducing the risk of operational failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"first-token\" data-sourcepos=\"1:1-1:129\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eJandy \u003cspan\u003eR0013200 \u003c\/span\u003ePressure Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eJandy \u003cspan\u003eR00457100 \u003c\/span\u003eTubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"first-token\" data-sourcepos=\"1:1-1:129\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJandy LXi Heater Models: \u003c\/strong\u003e\u003cspan\u003eLXI250N, LXI250NN, LXI400N, LXI400NN, LXI250NC, LXI250NS, LXI400NC, LXI400NS Natural and LXI250P, LXI250PN, LXI400P, LXI400PN, LXI250PC, LXI250PS, LXI400PC, LXI400PS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eThis pressure switch may be compatible with your system, please refer to your owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1625\" data-end=\"1644\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1646\" data-end=\"1719\" class=\"\"\u003eWater Pressure Sensor R0457000 – For Safe Jandy LXi Heater Operation\u003c\/h2\u003e\n\u003ch4 data-start=\"1720\" data-end=\"1789\" class=\"\"\u003eR0457000 turns off heater if water pressure falls out of range\u003c\/h4\u003e\n\u003ch4 data-start=\"1790\" data-end=\"1853\" class=\"\"\u003edesigned to stop gas ignition during low flow conditions\u003c\/h4\u003e\n\u003ch4 data-start=\"1854\" data-end=\"1919\" class=\"\"\u003eprevents fire hazard from clogged filters or failing pumps\u003c\/h4\u003e\n\u003ch4 data-start=\"1920\" data-end=\"1972\" class=\"\"\u003eused in LXi400P, LXi250N, and LXi400PC models\u003c\/h4\u003e\n\u003ch4 data-start=\"1973\" data-end=\"2039\" class=\"\"\u003efactory-tested switch includes tubing and sensor components\u003c\/h4\u003e\n\u003ch2 data-start=\"2041\" data-end=\"2110\" class=\"\"\u003eJandy R0457000 Pressure Switch – For Heater Water Flow Detection\u003c\/h2\u003e\n\u003ch4 data-start=\"2111\" data-end=\"2175\" class=\"\"\u003eswitch activates safety shutoff if circulation is too low\u003c\/h4\u003e\n\u003ch4 data-start=\"2176\" data-end=\"2234\" class=\"\"\u003efits all Jandy LXi heater models from 250k–400k BTU\u003c\/h4\u003e\n\u003ch4 data-start=\"2235\" data-end=\"2298\" class=\"\"\u003epart of heater startup diagnostics and ignition sequence\u003c\/h4\u003e\n\u003ch4 data-start=\"2299\" data-end=\"2363\" class=\"\"\u003eOEM component provides consistent readings under pressure\u003c\/h4\u003e\n\u003ch4 data-start=\"2364\" data-end=\"2430\" class=\"\"\u003eincludes flexible tubing for accurate inline flow detection\u003c\/h4\u003e\n\u003ch2 data-start=\"2432\" data-end=\"2507\" class=\"\"\u003eHeater Flow Monitoring Switch R0457000 – OEM Pressure Shutdown Control\u003c\/h2\u003e\n\u003ch4 data-start=\"2508\" data-end=\"2577\" class=\"\"\u003epart R0457000 used to detect pressure before heat cycle starts\u003c\/h4\u003e\n\u003ch4 data-start=\"2578\" data-end=\"2645\" class=\"\"\u003ereplace if heater errors out during priming or startup phase\u003c\/h4\u003e\n\u003ch4 data-start=\"2646\" data-end=\"2704\" class=\"\"\u003ecommon solution for flow errors and ignition delays\u003c\/h4\u003e\n\u003ch4 data-start=\"2705\" data-end=\"2761\" class=\"\"\u003efits behind access panel on Jandy LXi pool heater\u003c\/h4\u003e\n\u003ch4 data-start=\"2762\" data-end=\"2827\" class=\"\"\u003ecritical for both residential and commercial installations\u003c\/h4\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDiagram\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Jandy Water Pressure Switch For LXi Heaters | R0457000\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Water_Pressure_Switch_For_LXi_Heaters_R0457000_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732649688\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50597876760867,"sku":"R0457000","price":96.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Water_Pressure_Switch_For_LXi_Heaters_R0457000_Wholesale_Pool_Mart_1.jpg?v=1741037421"},{"product_id":"hayward-water-pressure-switch-for-fd-h-series-low-nox-heaters-fdxlwps1930","title":"Hayward FDXLWPS1930 Water Pressure Switch | For FD Heaters","description":"\u003cp class=\"\" data-end=\"2366\" data-start=\"1789\"\u003eOEM Hayward Water Pressure Switch FDXLWPS1930 ensures the safe and efficient function of Universal H-Series Low NOx pool heaters by disabling the unit when water circulation is interrupted. Compatible with a wide range of models including H150FDN, H200FDN, H250FDN, H300FDN, H350FDN, and H400FDN and their propane equivalents, this pressure switch is a direct replacement that helps avoid damage from dry firing or overheating. Built from durable materials and backed by Hayward’s OEM reliability, it’s simple to install and essential for preserving system safety and performance.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"2382\" data-start=\"2368\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-end=\"3051\" data-start=\"2384\"\u003e\n\u003cli class=\"\" data-end=\"2530\" data-start=\"2384\"\u003e\n\u003cp class=\"\" data-end=\"2530\" data-start=\"2386\"\u003e\u003cstrong data-end=\"2418\" data-start=\"2386\"\u003eProtects Against Dry Firing:\u003c\/strong\u003e Automatically interrupts heater function if water flow stops, helping prevent internal overheating or failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2665\" data-start=\"2531\"\u003e\n\u003cp class=\"\" data-end=\"2665\" data-start=\"2533\"\u003e\u003cstrong data-end=\"2562\" data-start=\"2533\"\u003eWide Model Compatibility:\u003c\/strong\u003e Works with Hayward models H150FDN through H400FDN, including propane heater versions for flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2791\" data-start=\"2666\"\u003e\n\u003cp class=\"\" data-end=\"2791\" data-start=\"2668\"\u003e\u003cstrong data-end=\"2698\" data-start=\"2668\"\u003eImproves System Longevity:\u003c\/strong\u003e Prevents avoidable wear or damage by ensuring heater only runs when proper flow is present\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2920\" data-start=\"2792\"\u003e\n\u003cp class=\"\" data-end=\"2920\" data-start=\"2794\"\u003e\u003cstrong data-end=\"2814\" data-start=\"2794\"\u003eEasy to Replace:\u003c\/strong\u003e Designed for a fast, hassle-free installation to restore vital safety functionality with minimal effort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"3051\" data-start=\"2921\"\u003e\n\u003cp class=\"\" data-end=\"3051\" data-start=\"2923\"\u003e\u003cstrong data-end=\"2953\" data-start=\"2923\"\u003eReliable OEM Construction:\u003c\/strong\u003e Genuine Hayward part manufactured for high performance, durability, and long-term dependability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eHayward FDXLWPS1930 Water Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward H-Series FD Low NOx Heater Models: \u003c\/strong\u003eH150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1166\" data-end=\"1185\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1187\" data-end=\"1228\" class=\"\"\u003eRecognizing Pressure Switch Failures\u003c\/h2\u003e\n\u003ch4 data-start=\"1229\" data-end=\"1279\" class=\"\"\u003esymptoms of bad pressure switch fdxlwps1930\u003c\/h4\u003e\n\u003ch4 data-start=\"1280\" data-end=\"1340\" class=\"\"\u003eheater starts then stops low pressure fix fdxlwps1930\u003c\/h4\u003e\n\u003ch4 data-start=\"1341\" data-end=\"1397\" class=\"\"\u003ewater not circulating fdxlwps1930 might be faulty\u003c\/h4\u003e\n\u003ch4 data-start=\"1398\" data-end=\"1452\" class=\"\"\u003eh250fdn heater shuts off quickly sensor problem\u003c\/h4\u003e\n\u003ch4 data-start=\"1453\" data-end=\"1507\" class=\"\"\u003epressure switch replacement for low nox heaters\u003c\/h4\u003e\n\u003ch2 data-start=\"1509\" data-end=\"1546\" class=\"\"\u003eCompatible Models and Swap Guide\u003c\/h2\u003e\n\u003ch4 data-start=\"1547\" data-end=\"1601\" class=\"\"\u003efdxlwps1930 used on hayward h400fdn and h400fdp\u003c\/h4\u003e\n\u003ch4 data-start=\"1602\" data-end=\"1655\" class=\"\"\u003ereplace water sensor on hayward h300fdn heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1656\" data-end=\"1713\" class=\"\"\u003elocal expert install fdxlwps1930 on hayward heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1714\" data-end=\"1766\" class=\"\"\u003ehow to remove old fdxlwps1930 pressure switch\u003c\/h4\u003e\n\u003ch4 data-start=\"1767\" data-end=\"1827\" class=\"\"\u003epropane heater pressure switch swap guide fdxlwps1930\u003c\/h4\u003e\n\u003ch2 data-start=\"1829\" data-end=\"1865\" class=\"\"\u003eFind It Nearby with Local Deals\u003c\/h2\u003e\n\u003ch4 data-start=\"1866\" data-end=\"1922\" class=\"\"\u003elowest local price for hayward fdxlwps1930 switch\u003c\/h4\u003e\n\u003ch4 data-start=\"1923\" data-end=\"1977\" class=\"\"\u003efdxlwps1930 water pressure switch near me cheap\u003c\/h4\u003e\n\u003ch4 data-start=\"1978\" data-end=\"2038\" class=\"\"\u003ehayward fd heater sensor available at wholesale store\u003c\/h4\u003e\n\u003ch4 data-start=\"2039\" data-end=\"2092\" class=\"\"\u003ebuy fdxlwps1930 from pool supply shop near you\u003c\/h4\u003e\n\u003ch4 data-start=\"2093\" data-end=\"2142\" class=\"\"\u003elocal inventory check for fdxlwps1930 part\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Water_Pressure_Switch_For_FD_H-Series_Low_NOx_Heaters_FDXLWPS1930_Wholesale_Pool_Mart_diagram_1ee594b1-f7c0-4151-948a-33b37aef4e4d_600x600.jpg?v=1732744508\" alt=\"Hayward Water Pressure Switch For FD H-Series Low NOx Heaters | FDXLWPS1930\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597879120163,"sku":"FDXLWPS1930","price":42.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Water_Pressure_Switch_For_FD_H-Series_Low_NOx_Heaters_FDXLWPS1930_Wholesale_Pool_Mart_2_000e60e7-a105-4936-a218-90e50ecc8600.jpg?v=1743529890"},{"product_id":"hayward-bypass-cartridge-kit-for-h-series-fd-heaters-fdxlbpk1930","title":"Hayward FDXLBPK1930 Bypass Cartridge Kit | FD Heaters","description":"\u003cp data-start=\"1836\" data-end=\"2392\" class=\"\"\u003eOEM Hayward Bypass Cartridge Kit FDXLBPK1930 is a key replacement part for maintaining consistent performance in Hayward Universal H-Series Low NOx pool heaters. Designed for models H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, and H400FDP, this kit regulates internal water bypass to prevent flow irregularities that may impact efficiency. It ensures balanced water circulation within the unit, helping preserve heat output and protect against unnecessary strain or damage over time.\u003c\/p\u003e\n\u003ch3 data-start=\"2394\" data-end=\"2408\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2410\" data-end=\"3128\"\u003e\n\u003cli data-start=\"2410\" data-end=\"2586\" class=\"\"\u003e\n\u003cp data-start=\"2412\" data-end=\"2586\" class=\"\"\u003e\u003cstrong data-start=\"2412\" data-end=\"2445\"\u003eComprehensive Model Coverage:\u003c\/strong\u003e Designed for Hayward models H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, and H400FDP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2587\" data-end=\"2725\" class=\"\"\u003e\n\u003cp data-start=\"2589\" data-end=\"2725\" class=\"\"\u003e\u003cstrong data-start=\"2589\" data-end=\"2616\"\u003eOptimizes Heating Flow:\u003c\/strong\u003e Controls internal water routing to improve heat transfer efficiency and reduce operational inconsistencies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2726\" data-end=\"2862\" class=\"\"\u003e\n\u003cp data-start=\"2728\" data-end=\"2862\" class=\"\"\u003e\u003cstrong data-start=\"2728\" data-end=\"2761\"\u003eProtects Internal Components:\u003c\/strong\u003e Prevents irregular water bypass that could lead to reduced heater performance or mechanical issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2863\" data-end=\"2995\" class=\"\"\u003e\n\u003cp data-start=\"2865\" data-end=\"2995\" class=\"\"\u003e\u003cstrong data-start=\"2865\" data-end=\"2897\"\u003eEnsures Long-Term Operation:\u003c\/strong\u003e Maintains proper circulation needed for sustained performance across various heating conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2996\" data-end=\"3128\" class=\"\"\u003e\n\u003cp data-start=\"2998\" data-end=\"3128\" class=\"\"\u003e\u003cstrong data-start=\"2998\" data-end=\"3027\"\u003eHayward Factory Standard:\u003c\/strong\u003e Genuine OEM part built to match exact heater specifications for dependable and lasting performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eCompatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward H-Series FD Heater Models: \u003c\/strong\u003eH150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, and H400FDP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1242\" data-start=\"1223\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 class=\"\" data-end=\"1281\" data-start=\"1244\"\u003eCommon Heater Symptoms and Fixes\u003c\/h2\u003e\n\u003ch4 class=\"\" data-end=\"1337\" data-start=\"1282\"\u003eh-series heater shuts off bypass cartridge issue\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1387\" data-start=\"1338\"\u003eheater flow rate drop fixed by fdxlbpk1930\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1446\" data-start=\"1388\"\u003ecartridge bypass stuck open fdxlbpk1930 replacement\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1504\" data-start=\"1447\"\u003elow heat output from hayward heater replace bypass\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1561\" data-start=\"1505\"\u003ewater bypass problem in h300fdn solved by new kit\u003c\/h4\u003e\n\u003ch2 class=\"\" data-end=\"1597\" data-start=\"1563\"\u003eConfirming Fit for Your Model\u003c\/h2\u003e\n\u003ch4 class=\"\" data-end=\"1651\" data-start=\"1598\"\u003ewill fdxlbpk1930 fit my h200fdp hayward heater\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1704\" data-start=\"1652\"\u003ecompatible heater models for fdxlbpk1930 part\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1760\" data-start=\"1705\"\u003ecartridge kit specs for universal low nox heater\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1803\" data-start=\"1761\"\u003ewhich bypass kit works with h350fdn\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1862\" data-start=\"1804\"\u003efdxlbpk1930 match for propane and natural gas units\u003c\/h4\u003e\n\u003ch2 class=\"\" data-end=\"1900\" data-start=\"1864\"\u003eLocal Pricing and Fast Sourcing\u003c\/h2\u003e\n\u003ch4 class=\"\" data-end=\"1951\" data-start=\"1901\"\u003ebest local price for fdxlbpk1930 bypass kit\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"2007\" data-start=\"1952\"\u003ehayward heater cartridge kit at wholesale supply\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"2048\" data-start=\"2008\"\u003efdxlbpk1930 available near me now\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"2099\" data-start=\"2049\"\u003echeck fdxlbpk1930 stock at local pool store\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"2158\" data-start=\"2100\"\u003ewhere to buy bypass kit for h-series heater locally\u003c\/h4\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597879284003,"sku":"FDXLBPK1930","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Bypass_Cartridge_Kit_For_H-Series_FD_Heaters_FDXLBPK1930_4.jpg?v=1736789544"},{"product_id":"hayward-pressure-switch-assembly-for-h-series-ed1-and-ed2-heaters-haxpsa1930","title":"Hayward HAXPSA1930 Pressure Switch | H-Series ED1 and ED2","description":"\u003cp data-start=\"1796\" data-end=\"2387\" class=\"\"\u003eOEM Hayward HAXPSA1930 Pressure Switch Assembly is designed to ensure safe and efficient operation of H-Series ED1 and ED2 pool heaters by monitoring system water pressure. When pressure falls below the necessary threshold, the switch automatically disables heater ignition to prevent damage from dry firing or inadequate flow. Its rugged build resists poolside wear, supporting dependable performance in residential and commercial settings. As a key safeguard in the heating system, this component helps preserve heater longevity and operational stability throughout demanding swim seasons.\u003c\/p\u003e\n\u003ch3 data-start=\"2389\" data-end=\"2405\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2406\" data-end=\"3084\"\u003e\n\u003cli data-start=\"2406\" data-end=\"2542\" class=\"\"\u003e\n\u003cp data-start=\"2408\" data-end=\"2542\" class=\"\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2448\"\u003eDirect OEM Fit for H-Series Heaters:\u003c\/strong\u003e Compatible with Hayward ED1 and ED2 models, maintaining proper pressure-based functionality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2543\" data-end=\"2691\" class=\"\"\u003e\n\u003cp data-start=\"2545\" data-end=\"2691\" class=\"\"\u003e\u003cstrong data-start=\"2545\" data-end=\"2576\"\u003eMonitors Water Circulation:\u003c\/strong\u003e Automatically disables ignition if flow is insufficient, preventing potential damage from low-pressure operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2692\" data-end=\"2817\" class=\"\"\u003e\n\u003cp data-start=\"2694\" data-end=\"2817\" class=\"\"\u003e\u003cstrong data-start=\"2694\" data-end=\"2723\"\u003eReliable Heating Control:\u003c\/strong\u003e Ensures heater functions only when conditions are safe, enhancing overall system protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2818\" data-end=\"2951\" class=\"\"\u003e\n\u003cp data-start=\"2820\" data-end=\"2951\" class=\"\"\u003e\u003cstrong data-start=\"2820\" data-end=\"2845\"\u003eDurable for Pool Use:\u003c\/strong\u003e Made with robust materials that endure moisture, heat, and chemical exposure for consistent reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2952\" data-end=\"3084\" class=\"\"\u003e\n\u003cp data-start=\"2954\" data-end=\"3084\" class=\"\"\u003e\u003cstrong data-start=\"2954\" data-end=\"2993\"\u003eEssential for Long-Term Efficiency:\u003c\/strong\u003e Plays a critical role in maintaining heater performance and avoiding unnecessary repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward H-Series Heaters\u003c\/li\u003e\n\u003cli\u003eHayward H-Series ED1 Heaters\u003c\/li\u003e\n\u003cli\u003eHayward H-Series ED2 Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-end=\"1163\" data-start=\"1144\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 class=\"\" data-end=\"1201\" data-start=\"1165\"\u003eTroubleshooting Low Flow Errors\u003c\/h2\u003e\n\u003ch4 class=\"\" data-end=\"1260\" data-start=\"1202\"\u003eh-series heater showing low flow error pressure fix\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1308\" data-start=\"1261\"\u003ereplace faulty haxpsa1930 on hayward ed2\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1362\" data-start=\"1309\"\u003eno ignition from hayward heater pressure issue\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1411\" data-start=\"1363\"\u003ewhen to replace haxpsa1930 in your heater\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1464\" data-start=\"1412\"\u003eheater runs cold pressure switch not engaging\u003c\/h4\u003e\n\u003ch2 class=\"\" data-end=\"1506\" data-start=\"1466\"\u003eCompatible Models and Install Notes\u003c\/h2\u003e\n\u003ch4 class=\"\" data-end=\"1563\" data-start=\"1507\"\u003ehaxpsa1930 fitment for ed1 and ed2 hayward models\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1616\" data-start=\"1564\"\u003ehow to install haxpsa1930 in millivolt heater\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1673\" data-start=\"1617\"\u003epart guide for hayward h-series pressure switches\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1723\" data-start=\"1674\"\u003epressure switch wiring tips for haxpsa1930\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1777\" data-start=\"1724\"\u003ewhich heater years are supported by haxpsa1930\u003c\/h4\u003e\n\u003ch2 class=\"\" data-end=\"1821\" data-start=\"1779\"\u003eFind Local Inventory and Good Pricing\u003c\/h2\u003e\n\u003ch4 class=\"\" data-end=\"1870\" data-start=\"1822\"\u003elocal price for haxpsa1930 hayward switch\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1926\" data-start=\"1871\"\u003ewhere to buy hayward ed1 pressure switch near me\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"1986\" data-start=\"1927\"\u003ewholesale pool parts dealer with haxpsa1930 in stock\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"2043\" data-start=\"1987\"\u003echeck local stock for haxpsa1930 replacement part\u003c\/h4\u003e\n\u003ch4 class=\"\" data-end=\"2101\" data-start=\"2044\"\u003ehayward h-series heater parts nearby at good price\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Pressure_Switch_Assembly_For_H-Series_ED1_and_ED2_Heaters_HAXPSA1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732638454\" alt=\"Hayward Pressure Switch Assembly For H-Series ED1 and ED2 Heaters | HAXPSA1930\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597880561955,"sku":"HAXPSA1930","price":76.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Pressure_Switch_Assembly_For_H-Series_ED1_and_ED2_Heaters_HAXPSA1930_Wholesale_Pool_Mart_1.jpg?v=1736789504"},{"product_id":"hayward-air-pressure-switch-for-h-series-induced-draft-heaters-idxaps1930","title":"Hayward IDXAPS1930 Air Pressure Switch | H-Series Heaters","description":"\u003cp\u003eThe OEM Hayward Air Pressure Switch IDXAPS1930 is a crucial component for ensuring the safe and efficient operation of Hayward H-Series Induced Draft pool heaters. This switch monitors and regulates the air pressure within the heating system, preventing overheating and ensuring that the heater operates at optimal performance levels. Made from high-quality, durable materials, it is designed to withstand the environmental conditions commonly found around pool equipment. Installation is straightforward, making it a reliable replacement part for maintaining your heater's safety and efficiency.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrucial Safety Component:\u003c\/strong\u003e The Hayward Air Pressure Switch IDXAPS1930 is essential for ensuring the safe and efficient operation of Hayward H-Series Induced Draft pool heaters, by monitoring and regulating the air pressure within the heating system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents Overheating:\u003c\/strong\u003e This switch plays a key role in preventing overheating by ensuring that the heater operates at optimal performance levels, maintaining safe and effective operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Constructed from high-quality, durable materials, the IDXAPS1930 is built to withstand the harsh environmental conditions typically encountered around pool equipment, ensuring long-lasting performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnsures Optimal Heater Performance:\u003c\/strong\u003e By regulating air pressure, this switch helps maintain the heater's efficiency and prevents potential malfunctions, contributing to the overall reliability of your heating system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Designed for straightforward installation, the IDXAPS1930 provides a convenient and reliable replacement option for maintaining your heater's safety and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eAir Pressure Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e Bracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e Screw\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward H-Series Induced Draft Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1220\" data-end=\"1239\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1241\" data-end=\"1280\" class=\"\"\u003eHeater Shutdown and Error Symptoms\u003c\/h2\u003e\n\u003ch4 data-start=\"1281\" data-end=\"1333\" class=\"\"\u003eair pressure lockout code fix with idxaps1930\u003c\/h4\u003e\n\u003ch4 data-start=\"1334\" data-end=\"1392\" class=\"\"\u003eheater won’t stay lit replace air switch idxaps1930\u003c\/h4\u003e\n\u003ch4 data-start=\"1393\" data-end=\"1446\" class=\"\"\u003ehow to diagnose hayward heater startup failure\u003c\/h4\u003e\n\u003ch4 data-start=\"1447\" data-end=\"1500\" class=\"\"\u003ecommon symptoms of air pressure switch failure\u003c\/h4\u003e\n\u003ch4 data-start=\"1501\" data-end=\"1559\" class=\"\"\u003ehayward h-series shuts off early air switch problem\u003c\/h4\u003e\n\u003ch2 data-start=\"1561\" data-end=\"1603\" class=\"\"\u003eEnsuring Compatibility and Proper Fit\u003c\/h2\u003e\n\u003ch4 data-start=\"1604\" data-end=\"1660\" class=\"\"\u003edoes idxaps1930 fit hayward induced draft heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1661\" data-end=\"1718\" class=\"\"\u003ereplacement air switch for millivolt style heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1719\" data-end=\"1773\" class=\"\"\u003ecorrect air pressure sensor for hayward systems\u003c\/h4\u003e\n\u003ch4 data-start=\"1774\" data-end=\"1827\" class=\"\"\u003elocal help matching idxaps1930 to heater model\u003c\/h4\u003e\n\u003ch4 data-start=\"1828\" data-end=\"1883\" class=\"\"\u003ehow to install air switch with bracket and screw\u003c\/h4\u003e\n\u003ch2 data-start=\"1885\" data-end=\"1926\" class=\"\"\u003eLocal Supply and Competitive Pricing\u003c\/h2\u003e\n\u003ch4 data-start=\"1927\" data-end=\"1979\" class=\"\"\u003elocal price for idxaps1930 hayward air switch\u003c\/h4\u003e\n\u003ch4 data-start=\"1980\" data-end=\"2029\" class=\"\"\u003ehayward heater air switch available nearby\u003c\/h4\u003e\n\u003ch4 data-start=\"2030\" data-end=\"2085\" class=\"\"\u003ebuy idxaps1930 at wholesale pool supply location\u003c\/h4\u003e\n\u003ch4 data-start=\"2086\" data-end=\"2140\" class=\"\"\u003echeck availability of idxaps1930 in local store\u003c\/h4\u003e\n\u003ch4 data-start=\"2141\" data-end=\"2196\" class=\"\"\u003ebest local price for hayward air pressure switch\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Hayward Air Pressure Switch For H-Series Induced Draft Heaters | IDXAPS1930\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Air_Pressure_Switch_For_H-Series_Induced_Draft_Heaters_IDXAPS1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732638924\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597882298659,"sku":"IDXAPS1930","price":75.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Air_Pressure_Switch_For_H-Series_Induced_Draft_Heaters_IDXAPS1930_Wholesale_Pool_Mart_1.jpg?v=1736789479"},{"product_id":"swimables-ignitor-for-hayward-h-series-above-ground-heaters-idxign1930-sw-42-020","title":"Swimables Ignitor For Hayward H-Series Above Ground Heaters | IDXIGN1930 | SW-42-020","description":"\u003cp\u003eThe Swimables Ignitor SW-42-020 is a critical component for H-Series above-ground pool heaters, designed to provide reliable ignition by igniting the gas and air mixture within the heater. It is constructed from durable materials to withstand high temperatures and ensure consistent performance over time. This replacement ignitor is essential for maintaining the safe and efficient operation of your Hayward pool heater, and it is relatively straightforward to install.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Ignition Component:\u003c\/strong\u003e The Swimables Ignitor SW-42-020 is an essential part for H-Series above-ground pool heaters, responsible for reliably igniting the gas and air mixture within the heater to initiate the heating process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Constructed from high-quality materials, this ignitor is built to withstand high temperatures and ensure consistent performance, contributing to the overall reliability of your heating system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnsures Safe Operation:\u003c\/strong\u003e By providing reliable ignition, the SW-42-020 plays a crucial role in maintaining the safe and efficient operation of your Hayward pool heater, preventing potential ignition issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStraightforward Installation:\u003c\/strong\u003e Designed for ease of use, this replacement ignitor is relatively simple to install, making it a convenient option for restoring your heater's functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintains Heater Efficiency:\u003c\/strong\u003e Essential for the proper operation of your pool heater, the ignitor ensures that the heating system runs smoothly and efficiently, enhancing the performance and longevity of your equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward H-Series Above Ground Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Swimables","offers":[{"title":"Default Title","offer_id":50597883478307,"sku":"SW-42-020","price":39.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/SwimablesIgnitorForHaywardH-SeriesAboveGroundHeatersIDXIGN1930SW-42-020WholesalePoolMart1.jpg?v=1736789443"},{"product_id":"hayward-ignitor-for-h-series-above-ground-heaters-idxign1930","title":"Hayward IDXIGN1930 Ignitor | For H-Series Heaters","description":"\u003cp data-start=\"1736\" data-end=\"2234\" class=\"\"\u003eOEM Hayward Ignitor IDXIGN1930 is engineered for use in Hayward H-Series Above Ground pool heaters, where it plays a key role in safely lighting the gas and air blend to begin the heating cycle. Manufactured with high-performance materials, it handles extreme temperatures and maintains consistent reliability throughout its service life. Simple to install, this ignitor is essential for keeping your heater operating efficiently, reducing downtime, and preserving system safety.\u003c\/p\u003e\n\u003ch3 data-start=\"2236\" data-end=\"2250\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2252\" data-end=\"2962\"\u003e\n\u003cli data-start=\"2252\" data-end=\"2399\" class=\"\"\u003e\n\u003cp data-start=\"2254\" data-end=\"2399\" class=\"\"\u003e\u003cstrong data-start=\"2254\" data-end=\"2294\"\u003eEngineered for Above Ground Systems:\u003c\/strong\u003e OEM fit for Hayward H-Series Above Ground pool heaters, offering precise compatibility and performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2400\" data-end=\"2544\" class=\"\"\u003e\n\u003cp data-start=\"2402\" data-end=\"2544\" class=\"\"\u003e\u003cstrong data-start=\"2402\" data-end=\"2427\"\u003eIgnites Fuel-Air Mix:\u003c\/strong\u003e Sparks the internal combustion needed to start the heating process and maintain effective pool temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2545\" data-end=\"2684\" class=\"\"\u003e\n\u003cp data-start=\"2547\" data-end=\"2684\" class=\"\"\u003e\u003cstrong data-start=\"2547\" data-end=\"2576\"\u003eMade for Heat Resistance:\u003c\/strong\u003e Fabricated from durable materials capable of resisting thermal stress common in gas-fired heating systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2685\" data-end=\"2822\" class=\"\"\u003e\n\u003cp data-start=\"2687\" data-end=\"2822\" class=\"\"\u003e\u003cstrong data-start=\"2687\" data-end=\"2719\"\u003eSupports Heater Reliability:\u003c\/strong\u003e Helps maintain stable and consistent heater performance by providing dependable ignition every cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2823\" data-end=\"2962\" class=\"\"\u003e\n\u003cp data-start=\"2825\" data-end=\"2962\" class=\"\"\u003e\u003cstrong data-start=\"2825\" data-end=\"2858\"\u003eQuick and Convenient Install:\u003c\/strong\u003e User-friendly design allows for an easy swap, reducing maintenance time and restoring heating quickly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward H-Series Above Ground Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1215\" data-end=\"1234\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1236\" data-end=\"1271\" class=\"\"\u003eCommon Heater Startup Problems\u003c\/h2\u003e\n\u003ch4 data-start=\"1272\" data-end=\"1327\" class=\"\"\u003eheater clicking but no flame install new ignitor\u003c\/h4\u003e\n\u003ch4 data-start=\"1328\" data-end=\"1380\" class=\"\"\u003eignition sequence fails idxign1930 may be bad\u003c\/h4\u003e\n\u003ch4 data-start=\"1381\" data-end=\"1430\" class=\"\"\u003ehayward h-series heater keeps shutting off\u003c\/h4\u003e\n\u003ch4 data-start=\"1431\" data-end=\"1485\" class=\"\"\u003esigns of failing ignitor in hayward pool heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1486\" data-end=\"1533\" class=\"\"\u003ehow to test heater ignitor functionality\u003c\/h4\u003e\n\u003ch2 data-start=\"1535\" data-end=\"1578\" class=\"\"\u003eConfirming Part Number and Heater Type\u003c\/h2\u003e\n\u003ch4 data-start=\"1579\" data-end=\"1636\" class=\"\"\u003eidxign1930 works with h-series above ground models\u003c\/h4\u003e\n\u003ch4 data-start=\"1637\" data-end=\"1691\" class=\"\"\u003eis idxign1930 correct for older hayward heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1692\" data-end=\"1743\" class=\"\"\u003ehow to install new ignitor on hayward heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1744\" data-end=\"1803\" class=\"\"\u003ecompatible ignitor for hayward h-series heater types\u003c\/h4\u003e\n\u003ch4 data-start=\"1804\" data-end=\"1845\" class=\"\"\u003ewhich ignitor fits my hayward unit\u003c\/h4\u003e\n\u003ch2 data-start=\"1847\" data-end=\"1888\" class=\"\"\u003eLocal Pricing and Stock Availability\u003c\/h2\u003e\n\u003ch4 data-start=\"1889\" data-end=\"1942\" class=\"\"\u003ebest local price for idxign1930 heater ignitor\u003c\/h4\u003e\n\u003ch4 data-start=\"1943\" data-end=\"1989\" class=\"\"\u003ewhere to buy idxign1930 ignitor near me\u003c\/h4\u003e\n\u003ch4 data-start=\"1990\" data-end=\"2048\" class=\"\"\u003ewholesale pool supply has hayward ignitors in stock\u003c\/h4\u003e\n\u003ch4 data-start=\"2049\" data-end=\"2092\" class=\"\"\u003echeck local inventory for idxign1930\u003c\/h4\u003e\n\u003ch4 data-start=\"2093\" data-end=\"2149\" class=\"\"\u003efind hayward replacement parts at local warehouse\u003c\/h4\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597883838755,"sku":"IDXIGN1930","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Ignitor_For_H-Series_Above_Ground_Heaters_IDXIGN1930_Wholesale_Pool_Mart_1.jpg?v=1736789433"},{"product_id":"swimables-thermistor-for-hayward-h-series-heaters-idxlter1930-sw-42-930","title":"Swimables Thermistor For Hayward H-Series Heaters | IDXLTER1930 | SW-42-930","description":"\u003cp\u003eThe Swimables Thermistor SW-42-930 is a critical component for maintaining accurate temperature readings in Hayward H-Series pool heaters, particularly the Low NOx Induced Draft and ED2 models. This thermistor helps regulate the heater by monitoring the water temperature, ensuring it stays within safe operating limits. If your heater's control panel is displaying incorrect temperature readings, it may be time to replace the thermistor. Compatible with a wide range of Hayward H-Series heaters, this replacement part is easy to install and essential for the reliable operation of your pool heating system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Temperature Monitoring Component:\u003c\/strong\u003e The Swimables Thermistor SW-42-930 is essential for maintaining accurate temperature readings in Hayward H-Series pool heaters, specifically for Low NOx Induced Draft and ED2 models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulates Heater Operation:\u003c\/strong\u003e This thermistor plays a crucial role in regulating the heater by continuously monitoring the water temperature and ensuring it remains within safe operating limits, which is vital for proper heater function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Incorrect Readings:\u003c\/strong\u003e If your heater's control panel is displaying incorrect temperature readings, replacing the thermistor is often necessary to restore accurate temperature measurement and reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Compatibility:\u003c\/strong\u003e Designed to work with a broad range of Hayward H-Series heaters, this thermistor ensures compatibility and easy integration into your existing system, providing a hassle-free replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e The SW-42-930 is straightforward to install, making it a practical choice for both professionals and DIY enthusiasts seeking to maintain the efficiency and accuracy of their pool heating system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eSwimables SW-42-930 Thermistor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward H-Series Heaters\u003c\/li\u003e\n\u003cli\u003eHayward H-Series Induced Draft Heaters\u003c\/li\u003e\n\u003cli\u003eHayward H-Series ED2 Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eThis Thermistor may be compatible with your system, please refer to your owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e","brand":"Swimables","offers":[{"title":"Default Title","offer_id":50597890064675,"sku":"SW-42-930","price":22.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/SwimablesThermistorForHaywardH-SeriesHeatersIDXLTER1930SW-42-930WholesalePoolMart1.jpg?v=1736789357"},{"product_id":"hayward-thermistor-for-h-series-heaters-idxlter1930","title":"Hayward IDXLTER1930 Thermistor | For H-Series Heaters","description":"\u003cp data-start=\"1721\" data-end=\"2246\" class=\"\"\u003eOEM Hayward Thermistor IDXLTER1930 is engineered for accurate temperature sensing in Hayward H-Series Low NOx Induced Draft and ED2 pool heaters. This thermistor monitors water temperature to regulate heating cycles and prevent overheating. If your control panel displays incorrect temperature values, this part is often the necessary fix. It is a genuine Hayward replacement with wide model compatibility, built to maintain consistent performance and easy to install for restoring proper heater operation.\u003c\/p\u003e\n\u003ch3 data-start=\"2248\" data-end=\"2262\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2264\" data-end=\"2925\"\u003e\n\u003cli data-start=\"2264\" data-end=\"2407\" class=\"\"\u003e\n\u003cp data-start=\"2266\" data-end=\"2407\" class=\"\"\u003e\u003cstrong data-start=\"2266\" data-end=\"2298\"\u003eFor ED2 and Low NOx Heaters:\u003c\/strong\u003e Specifically designed to work with Hayward H-Series Induced Draft and ED2 models for trusted compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2408\" data-end=\"2533\" class=\"\"\u003e\n\u003cp data-start=\"2410\" data-end=\"2533\" class=\"\"\u003e\u003cstrong data-start=\"2410\" data-end=\"2439\"\u003eRegulates Heating Cycles:\u003c\/strong\u003e Provides real-time water temperature feedback to control and maintain optimal heater output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2534\" data-end=\"2669\" class=\"\"\u003e\n\u003cp data-start=\"2536\" data-end=\"2669\" class=\"\"\u003e\u003cstrong data-start=\"2536\" data-end=\"2568\"\u003eCorrects Temperature Faults:\u003c\/strong\u003e Replacing the thermistor can fix erratic temperature readings and restore accurate digital display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2670\" data-end=\"2797\" class=\"\"\u003e\n\u003cp data-start=\"2672\" data-end=\"2797\" class=\"\"\u003e\u003cstrong data-start=\"2672\" data-end=\"2697\"\u003eGenuine Hayward Part:\u003c\/strong\u003e OEM design ensures the thermistor performs reliably under harsh poolside environmental conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2798\" data-end=\"2925\" class=\"\"\u003e\n\u003cp data-start=\"2800\" data-end=\"2925\" class=\"\"\u003e\u003cstrong data-start=\"2800\" data-end=\"2829\"\u003eFast Installation Option:\u003c\/strong\u003e Installs easily for quick restoration of essential monitoring and system regulation functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eHayward IDXLTER1930 Thermistor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward H-Series Heaters\u003c\/li\u003e\n\u003cli\u003eHayward H-Series Induced Draft Heaters\u003c\/li\u003e\n\u003cli\u003eHayward H-Series ED2 Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan\u003eThis Thermistor may be compatible with your system, please refer to your owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1245\" data-end=\"1264\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1266\" data-end=\"1306\" class=\"\"\u003eTroubleshooting Thermistor Failures\u003c\/h2\u003e\n\u003ch4 data-start=\"1307\" data-end=\"1367\" class=\"\"\u003etemp reading stuck or erratic hayward fix idxlter1930\u003c\/h4\u003e\n\u003ch4 data-start=\"1368\" data-end=\"1426\" class=\"\"\u003eheater overheating due to failed temperature sensor\u003c\/h4\u003e\n\u003ch4 data-start=\"1427\" data-end=\"1479\" class=\"\"\u003ehow to replace faulty thermistor in ed2 model\u003c\/h4\u003e\n\u003ch4 data-start=\"1480\" data-end=\"1532\" class=\"\"\u003esigns your hayward thermistor needs replacing\u003c\/h4\u003e\n\u003ch4 data-start=\"1533\" data-end=\"1587\" class=\"\"\u003ehayward low nox heater control panel error code\u003c\/h4\u003e\n\u003ch2 data-start=\"1589\" data-end=\"1631\" class=\"\"\u003eFitment Support and Installation Tips\u003c\/h2\u003e\n\u003ch4 data-start=\"1632\" data-end=\"1686\" class=\"\"\u003eidxlter1930 compatible with h-series ed2 models\u003c\/h4\u003e\n\u003ch4 data-start=\"1687\" data-end=\"1745\" class=\"\"\u003ehow to install hayward temperature sensor correctly\u003c\/h4\u003e\n\u003ch4 data-start=\"1746\" data-end=\"1798\" class=\"\"\u003econfirm idxlter1930 matches your heater model\u003c\/h4\u003e\n\u003ch4 data-start=\"1799\" data-end=\"1844\" class=\"\"\u003equick guide to swap hayward thermistor\u003c\/h4\u003e\n\u003ch4 data-start=\"1845\" data-end=\"1898\" class=\"\"\u003ewhat comes with idxlter1930 thermistor package\u003c\/h4\u003e\n\u003ch2 data-start=\"1900\" data-end=\"1934\" class=\"\"\u003eLocal Supply and Pricing Info\u003c\/h2\u003e\n\u003ch4 data-start=\"1935\" data-end=\"1984\" class=\"\"\u003ebest local price on idxlter1930 thermistor\u003c\/h4\u003e\n\u003ch4 data-start=\"1985\" data-end=\"2046\" class=\"\"\u003ehayward heater sensor available at wholesale pool mart\u003c\/h4\u003e\n\u003ch4 data-start=\"2047\" data-end=\"2100\" class=\"\"\u003echeck nearby availability for idxlter1930 part\u003c\/h4\u003e\n\u003ch4 data-start=\"2101\" data-end=\"2153\" class=\"\"\u003epurchase replacement thermistor at local shop\u003c\/h4\u003e\n\u003ch4 data-start=\"2154\" data-end=\"2208\" class=\"\"\u003epool heater temperature sensor near me in stock\u003c\/h4\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597891703075,"sku":"IDXLTER1930","price":72.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Thermistor_For_H-Series_Heaters_IDXLTER1930_Wholesale_Pool_Mart_1.jpg?v=1736789351"},{"product_id":"hayward-vent-pressure-switch-for-h-series-heaters-idxlvps1930","title":"Hayward IDXLVPS1930 Vent Pressure Switch | H-Series Heaters","description":"\u003cp data-start=\"1794\" data-end=\"2342\" class=\"\"\u003eOEM Hayward Vent Pressure Switch IDXLVPS1930 is designed for Hayward Universal H-Series Low NOx pool and spa heaters to help prevent system damage caused by negative pressure. This critical safety switch shuts off heater operation if pressure drops to unsafe levels, ensuring reliable performance and system protection. Its corrosion-resistant build makes it suitable for use in chemical-rich or saltwater environments. With easy installation and OEM-quality reliability, this switch plays a key role in preserving heater safety.\u003c\/p\u003e\n\u003ch3 data-start=\"2344\" data-end=\"2358\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2360\" data-end=\"3058\"\u003e\n\u003cli data-start=\"2360\" data-end=\"2510\" class=\"\"\u003e\n\u003cp data-start=\"2362\" data-end=\"2510\" class=\"\"\u003e\u003cstrong data-start=\"2362\" data-end=\"2397\"\u003eEngineered for Low NOx Heaters:\u003c\/strong\u003e Specifically built for Universal H-Series Low NOx models for precise pressure monitoring and system protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2511\" data-end=\"2646\" class=\"\"\u003e\n\u003cp data-start=\"2513\" data-end=\"2646\" class=\"\"\u003e\u003cstrong data-start=\"2513\" data-end=\"2559\"\u003eProtects Heater from Low Pressure Hazards:\u003c\/strong\u003e Responds to unsafe negative pressure to help avoid internal system strain or failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2647\" data-end=\"2784\" class=\"\"\u003e\n\u003cp data-start=\"2649\" data-end=\"2784\" class=\"\"\u003e\u003cstrong data-start=\"2649\" data-end=\"2688\"\u003eDurable Against Harsh Environments:\u003c\/strong\u003e Made from materials that withstand chemical and saltwater exposure for long-lasting operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2785\" data-end=\"2922\" class=\"\"\u003e\n\u003cp data-start=\"2787\" data-end=\"2922\" class=\"\"\u003e\u003cstrong data-start=\"2787\" data-end=\"2823\"\u003eQuick Installation Kit Included:\u003c\/strong\u003e Includes mounting bracket and screws for fast replacement with minimal effort or system downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2923\" data-end=\"3058\" class=\"\"\u003e\n\u003cp data-start=\"2925\" data-end=\"3058\" class=\"\"\u003e\u003cstrong data-start=\"2925\" data-end=\"2956\"\u003eEssential for Safe Heating:\u003c\/strong\u003e Maintains critical pressure levels to keep the heater functioning safely and efficiently year-round\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePressure Switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eBracket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eScrews\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHayward Universal H-Series Low NOx Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1198\" data-end=\"1217\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1219\" data-end=\"1262\" class=\"\"\u003eSigns of a Faulty Vent Pressure Switch\u003c\/h2\u003e\n\u003ch4 data-start=\"1263\" data-end=\"1316\" class=\"\"\u003ehayward heater stuck in startup pressure issue\u003c\/h4\u003e\n\u003ch4 data-start=\"1317\" data-end=\"1374\" class=\"\"\u003event pressure switch failure symptoms low nox unit\u003c\/h4\u003e\n\u003ch4 data-start=\"1375\" data-end=\"1421\" class=\"\"\u003ereplace idxlvps1930 if heater won’t run\u003c\/h4\u003e\n\u003ch4 data-start=\"1422\" data-end=\"1478\" class=\"\"\u003estartup sequence fails due to bad pressure switch\u003c\/h4\u003e\n\u003ch4 data-start=\"1479\" data-end=\"1536\" class=\"\"\u003ehow to diagnose vent switch problem in pool heater\u003c\/h4\u003e\n\u003ch2 data-start=\"1538\" data-end=\"1582\" class=\"\"\u003eConfirming Heater Compatibility and Fit\u003c\/h2\u003e\n\u003ch4 data-start=\"1583\" data-end=\"1641\" class=\"\"\u003eidxlvps1930 fits universal h-series low nox heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1642\" data-end=\"1698\" class=\"\"\u003einstallation tips for hayward vent switch bracket\u003c\/h4\u003e\n\u003ch4 data-start=\"1699\" data-end=\"1751\" class=\"\"\u003epart number match for vent switch replacement\u003c\/h4\u003e\n\u003ch4 data-start=\"1752\" data-end=\"1803\" class=\"\"\u003ehow to install idxlvps1930 in hayward heater\u003c\/h4\u003e\n\u003ch4 data-start=\"1804\" data-end=\"1858\" class=\"\"\u003econfirm fitment for idxlvps1930 on older models\u003c\/h4\u003e\n\u003ch2 data-start=\"1860\" data-end=\"1904\" class=\"\"\u003eLocal Inventory and Competitive Pricing\u003c\/h2\u003e\n\u003ch4 data-start=\"1905\" data-end=\"1958\" class=\"\"\u003efind idxlvps1930 switch at wholesale pool mart\u003c\/h4\u003e\n\u003ch4 data-start=\"1959\" data-end=\"2010\" class=\"\"\u003elocal price for hayward vent pressure switch\u003c\/h4\u003e\n\u003ch4 data-start=\"2011\" data-end=\"2059\" class=\"\"\u003ebuy pool heater switch at nearby supplier\u003c\/h4\u003e\n\u003ch4 data-start=\"2060\" data-end=\"2117\" class=\"\"\u003estock available now for idxlvps1930 in local store\u003c\/h4\u003e\n\u003ch4 data-start=\"2118\" data-end=\"2173\" class=\"\"\u003echeck warehouse supply for pressure switch parts\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Hayward Vent Pressure Switch For H-Series Heaters | IDXLVPS1930\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Vent_Pressure_Switch_For_H-Series_Heaters_IDXLVPS1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732638197\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50597904941347,"sku":"IDXLVPS1930","price":95.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Vent_Pressure_Switch_For_H-Series_Heaters_IDXLVPS1930_Wholesale_Pool_Mart_1.jpg?v=1736789305"},{"product_id":"hayward-thermistor-for-universal-h-series-low-nox-heaters-fdxlter1930","title":"Hayward FDXLTER1930 Thermistor | For H-Series FD Heaters","description":"\u003cp data-start=\"1768\" data-end=\"2321\" class=\"\"\u003eOEM Hayward Thermistor FDXLTER1930 is a genuine replacement sensor designed to monitor water temperature in Hayward Universal H-Series Low NOx pool heaters. It fits models including H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, and H500FD. Installed in the manifold adapter inlet, it helps control the combustion air blower to maintain stable and efficient heating. Durable and easy to install, this thermistor supports accurate operation and long-term system performance.\u003c\/p\u003e\n\u003ch3 data-start=\"2323\" data-end=\"2337\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2339\" data-end=\"2999\"\u003e\n\u003cli data-start=\"2339\" data-end=\"2474\" class=\"\"\u003e\n\u003cp data-start=\"2341\" data-end=\"2474\" class=\"\"\u003e\u003cstrong data-start=\"2341\" data-end=\"2373\"\u003eCovers Wide Range of Models:\u003c\/strong\u003e Compatible with Hayward H-Series Low NOx models from H150FDN to H500FD for maximum system coverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2475\" data-end=\"2604\" class=\"\"\u003e\n\u003cp data-start=\"2477\" data-end=\"2604\" class=\"\"\u003e\u003cstrong data-start=\"2477\" data-end=\"2510\"\u003eManages Temperature Feedback:\u003c\/strong\u003e Acts as a sensor for water temperature, helping modulate heater output and blower operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2605\" data-end=\"2738\" class=\"\"\u003e\n\u003cp data-start=\"2607\" data-end=\"2738\" class=\"\"\u003e\u003cstrong data-start=\"2607\" data-end=\"2639\"\u003eSupports Consistent Heating:\u003c\/strong\u003e Helps maintain desired pool water temperature by regulating combustion based on thermal readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2739\" data-end=\"2863\" class=\"\"\u003e\n\u003cp data-start=\"2741\" data-end=\"2863\" class=\"\"\u003e\u003cstrong data-start=\"2741\" data-end=\"2768\"\u003eLong-Lasting Component:\u003c\/strong\u003e Constructed with quality materials for resistance to corrosion and high-temperature exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2864\" data-end=\"2999\" class=\"\"\u003e\n\u003cp data-start=\"2866\" data-end=\"2999\" class=\"\"\u003e\u003cstrong data-start=\"2866\" data-end=\"2896\"\u003eOEM Replacement Assurance:\u003c\/strong\u003e Ensures a precise fit and reliable function, restoring proper control to your Hayward heating system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e Hayward FDXLTER1930 Thermistor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHayward H-Series FD Heaters Models:\u003c\/span\u003e\u003c\/strong\u003e H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, H500FD\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1228\" data-end=\"1247\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1249\" data-end=\"1292\" class=\"\"\u003eHeater Performance and Temp Regulation\u003c\/h2\u003e\n\u003ch4 data-start=\"1293\" data-end=\"1346\" class=\"\"\u003eheater not holding temp sensor needs replacing\u003c\/h4\u003e\n\u003ch4 data-start=\"1347\" data-end=\"1405\" class=\"\"\u003ehow thermistor affects hayward pool heater function\u003c\/h4\u003e\n\u003ch4 data-start=\"1406\" data-end=\"1462\" class=\"\"\u003einconsistent heating trace to fdxlter1930 failure\u003c\/h4\u003e\n\u003ch4 data-start=\"1463\" data-end=\"1519\" class=\"\"\u003ehow to know if your temp sensor is malfunctioning\u003c\/h4\u003e\n\u003ch4 data-start=\"1520\" data-end=\"1573\" class=\"\"\u003epoor blower timing caused by faulty thermistor\u003c\/h4\u003e\n\u003ch2 data-start=\"1575\" data-end=\"1616\" class=\"\"\u003eFitment for Local Pool Heater Models\u003c\/h2\u003e\n\u003ch4 data-start=\"1617\" data-end=\"1674\" class=\"\"\u003efdxlter1930 compatible with all fdn and fdp models\u003c\/h4\u003e\n\u003ch4 data-start=\"1675\" data-end=\"1724\" class=\"\"\u003epart fits hayward h250fdn, h300fdp, h500fd\u003c\/h4\u003e\n\u003ch4 data-start=\"1725\" data-end=\"1785\" class=\"\"\u003efind thermistor for universal h-series heater locally\u003c\/h4\u003e\n\u003ch4 data-start=\"1786\" data-end=\"1838\" class=\"\"\u003einstallation tips for fdxlter1930 replacement\u003c\/h4\u003e\n\u003ch4 data-start=\"1839\" data-end=\"1890\" class=\"\"\u003eensure correct placement in manifold adapter\u003c\/h4\u003e\n\u003ch2 data-start=\"1892\" data-end=\"1928\" class=\"\"\u003eLocal Pricing and Stock Options\u003c\/h2\u003e\n\u003ch4 data-start=\"1929\" data-end=\"1986\" class=\"\"\u003efind fdxlter1930 thermistor at wholesale pool mart\u003c\/h4\u003e\n\u003ch4 data-start=\"1987\" data-end=\"2036\" class=\"\"\u003ebest price locally for hayward temp sensor\u003c\/h4\u003e\n\u003ch4 data-start=\"2037\" data-end=\"2083\" class=\"\"\u003echeck nearby store for thermistor stock\u003c\/h4\u003e\n\u003ch4 data-start=\"2084\" data-end=\"2136\" class=\"\"\u003epool heater sensor in stock at local supplier\u003c\/h4\u003e\n\u003ch4 data-start=\"2137\" data-end=\"2185\" class=\"\"\u003ebuy fdxlter1930 at nearby pool parts shop\u003c\/h4\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"Hayward Thermistor For Universal H-Series Low Nox Heaters | FDXLTER1930\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Thermistor_For_Universal_H-Series_Low_Nox_Heaters_FDXLTER1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732744553\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50598172000547,"sku":"FDXLTER1930","price":44.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Thermistor_For_Universal_H-Series_Low_Nox_Heaters_FDXLTER1930_Wholesale_Pool_Mart_1.jpg?v=1736789261"},{"product_id":"raypak-pressure-switch-for-heaters-11-psi-009133f","title":"Raypak 009133F Pressure Switch | 11 PSI Heaters","description":"\u003cp data-start=\"1918\" data-end=\"2496\"\u003eThe Raypak 009133F Pressure Switch is an OEM-rated 11 PSI safety device used in Raypak heater models 185A, 206A\/207A, 265A\/266A\/267A, 335A\/336A\/337A, and 405A\/406A\/407A. This component ensures the heater only operates when safe water pressure levels are present, shutting down the system when conditions fall outside factory thresholds. Built with durable construction for reliability, it preserves heater efficiency while safeguarding against overheating or system damage. Installing this OEM pressure switch restores proper functionality and long-term safety to your heater.\u003c\/p\u003e\n\u003ch3 data-start=\"2498\" data-end=\"2514\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2516\" data-end=\"3247\"\u003e\n\u003cli data-start=\"2516\" data-end=\"2657\"\u003e\n\u003cp data-start=\"2518\" data-end=\"2657\"\u003e\u003cstrong data-start=\"2518\" data-end=\"2544\"\u003eCompatible OEM Design:\u003c\/strong\u003e Engineered for Raypak 185A–407A heater families, offering reliable factory-grade fit and dependable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2658\" data-end=\"2806\"\u003e\n\u003cp data-start=\"2660\" data-end=\"2806\"\u003e\u003cstrong data-start=\"2660\" data-end=\"2688\"\u003e11 PSI Control Function:\u003c\/strong\u003e Switches the heater on or off automatically at 11 PSI, providing consistent pressure regulation for safe operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2807\" data-end=\"2947\"\u003e\n\u003cp data-start=\"2809\" data-end=\"2947\"\u003e\u003cstrong data-start=\"2809\" data-end=\"2846\"\u003eReliable, Long-Term Construction:\u003c\/strong\u003e Designed to resist poolside stress, moisture, and heat for accurate pressure monitoring over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2948\" data-end=\"3098\"\u003e\n\u003cp data-start=\"2950\" data-end=\"3098\"\u003e\u003cstrong data-start=\"2950\" data-end=\"2981\"\u003ePrevents Unsafe Conditions:\u003c\/strong\u003e Stops heater operation when water flow or pressure is inadequate, protecting internal components from overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3099\" data-end=\"3247\"\u003e\n\u003cp data-start=\"3101\" data-end=\"3247\"\u003e\u003cstrong data-start=\"3101\" data-end=\"3139\"\u003eMaintains Efficiency \u0026amp; Compliance:\u003c\/strong\u003e Ensures system pressure remains within proper levels, supporting heater performance and safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Digital Heater Models: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e206A, 266A, 336A, 406A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRaypak Digital Low Nox Heater Models: \u003c\/strong\u003e207A, 267A, 337A, 407A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRaypak Heater Models: \u003c\/strong\u003e185A, 265A, 335A, 405A\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This pressure switch may be compatible with your heater, please refer to your systems owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"2015\" data-end=\"2036\"\u003eAdditional Info\u003c\/h3\u003e\n\u003cp data-start=\"2037\" data-end=\"2229\"\u003eLooking for the Raypak 009133F Pressure Switch for 11 PSI heaters? This section explains installation tips, troubleshooting concerns, and how to confirm stock and pricing at local suppliers.\u003c\/p\u003e\n\u003ch2 data-start=\"2231\" data-end=\"2270\"\u003eInstallation Tips for Local Buyers\u003c\/h2\u003e\n\u003cp data-start=\"2271\" data-end=\"2440\"\u003eThe 009133F is designed for precise water-pressure monitoring. Local buyers often ask about calibration, wiring setup, and compatibility with digital vs Low-NOx units.\u003c\/p\u003e\n\u003ch4 data-start=\"2441\" data-end=\"2516\"\u003eHow to replace Raypak 009133F pressure switch on 207A heater near me\u003c\/h4\u003e\n\u003ch4 data-start=\"2517\" data-end=\"2585\"\u003eDo local shops stock wire connectors for 009133F installation\u003c\/h4\u003e\n\u003ch4 data-start=\"2586\" data-end=\"2651\"\u003eCorrect calibration steps for 009133F switch on 336A model\u003c\/h4\u003e\n\u003ch4 data-start=\"2652\" data-end=\"2722\"\u003eLocal guide for mounting 009133F pressure switch on 185A heater\u003c\/h4\u003e\n\u003ch2 data-start=\"2724\" data-end=\"2760\"\u003eCommon Issues After Replacement\u003c\/h2\u003e\n\u003cp data-start=\"2761\" data-end=\"2918\"\u003eIf problems continue, they may stem from clogged plumbing, pump priming issues, or loose electrical leads. These are common concerns raised by technicians.\u003c\/p\u003e\n\u003ch4 data-start=\"2919\" data-end=\"2988\"\u003eRaypak 265A still shows low pressure after 009133F replacement\u003c\/h4\u003e\n\u003ch4 data-start=\"2989\" data-end=\"3054\"\u003eWhy does 009133F not activate heater on 405A digital model\u003c\/h4\u003e\n\u003ch4 data-start=\"3055\" data-end=\"3120\"\u003eCan worn pump seals cause false readings on 009133F switch\u003c\/h4\u003e\n\u003ch4 data-start=\"3121\" data-end=\"3191\"\u003eLocal troubleshooting for 009133F heater pressure switch faults\u003c\/h4\u003e\n\u003ch2 data-start=\"3193\" data-end=\"3228\"\u003eChecking Local Price and Stock\u003c\/h2\u003e\n\u003cp data-start=\"3229\" data-end=\"3364\"\u003eCheck your model and confirm with local suppliers before purchase. Availability is usually good, but pricing may vary by distributor.\u003c\/p\u003e\n\u003ch4 data-start=\"3365\" data-end=\"3439\"\u003eCheck local price Raypak 009133F pressure switch for 11 PSI heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"3440\" data-end=\"3500\"\u003eWhich nearby supplier carries 009133F switch in stock\u003c\/h4\u003e\n\u003ch4 data-start=\"3501\" data-end=\"3562\"\u003eCompare cost of 009133F at local pool equipment stores\u003c\/h4\u003e\n\u003ch4 data-start=\"3563\" data-end=\"3636\"\u003eConfirm local availability of 009133F switch before visiting store\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Pressure_Switch_For_Heaters_11_PSI_009133F_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732749493\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599473086755,"sku":"009133F","price":37.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Pressure_Switch_For_Heaters_11_PSI_009133F_Wholesale_Pool_Mart_1.jpg?v=1738619415"},{"product_id":"raypak-bypass-kit-for-heaters-006715f","title":"Raypak Bypass Kit For Heaters | 006715F","description":"\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Bypass_Kit_For_Heaters_006715F_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732748315\"\u003e\u003c\/div\u003e\n\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe OEM Raypak Bypass Kit for Low NOx Heaters, model 006715F, is designed to enhance the efficiency and longevity of your heating system by regulating water flow. This bypass kit helps maintain optimal temperature and performance of your Low NOx heaters by preventing overheating and reducing wear on the components. Easy to install and crafted from durable materials, the Raypak Bypass Kit ensures reliable operation, making it an essential addition for maintaining the health of your low-emission heating system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances Efficiency and Longevity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to regulate water flow effectively, this bypass kit enhances both the efficiency and lifespan of your heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePrevents Overheating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps maintain optimal temperature and performance by preventing overheating, reducing wear and tear on your Low NOx heaters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEasy Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Simple to install, making it a convenient addition for both new installations and retrofits in existing systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCrafted from Durable Materials:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Made from robust and long-lasting materials, ensuring reliable operation and minimal maintenance over time.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEssential for Low-Emission Systems:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A crucial component for maintaining the health and efficiency of your low-emission heating system, ensuring it operates at peak performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eRaypak Bypass Valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eRaypak Bypass Dam\/Shaft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eBypass Springs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Digital Heater Models: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e206A, 266A, 336A, 406A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRaypak Digital Low Nox Heater Models: \u003c\/strong\u003e207A, 267A, 337A, 407A\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003eRaypak Heater Models: \u003c\/strong\u003e185A, 265A, 335A, 405A\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599526498595,"sku":"006715F","price":46.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/RaypakBypassKitForHeaters006715FWholesalePoolMart1.jpg?v=1738619123"},{"product_id":"raypak-natural-gas-on-off-gas-valve-for-low-nox-heaters-010329f","title":"Raypak Natural Gas On\/Off Gas Valve For Low Nox Heaters | 010329F","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe Raypak Natural Gas Combination Gas Valve for Low NOx Heaters, model 010329F, is a reliable and efficient on\/off control valve designed to regulate the flow of natural gas into your heating system. This valve ensures precise control and safe operation, contributing to reduced nitrogen oxide emissions and compliance with environmental standards. By using the Raypak Combination Gas Valve, you enhance the performance and operational control of your Low NOx heater, ensuring efficient combustion and consistent heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eReliable and Efficient Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Acts as a dependable on\/off control valve to regulate the flow of natural gas into your heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnsures Precise Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Offers precise control and safe operation, significantly enhancing the performance of your Low NOx heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eReduces Emissions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Contributes to reduced nitrogen oxide emissions, helping ensure compliance with stringent environmental standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances Combustion Efficiency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ensures efficient combustion and consistent heating, optimizing the overall performance of your heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eImproves Operational Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e By integrating this gas valve, you gain better operational control, contributing to the longevity and reliability of your heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Low Nox Heaters:\u003c\/span\u003e\u003c\/strong\u003e 207A, 267A, 337A, 407A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This gas valve may be compatible with your heater, please refer to your systems owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Natural_Gas_OnOff_Gas_Valve_For_Low_Nox_Heaters_010329F_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732749319\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599550320931,"sku":"010329F","price":219.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Natural_Gas_OnOff_Gas_Valve_For_Low_Nox_Heaters_010329F_Wholesale_Pool_Mart_1.jpg?v=1738618980"},{"product_id":"raypak-high-limit-140f-auto-reset-for-low-nox-heaters-600893b","title":"Raypak High Limit 140F Auto Reset For Low Nox Heaters | 600893B","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe OEM Raypak High Limit 140F Auto Reset, model 600893B, is specifically designed for Low NOx heaters to ensure safe and efficient operation. This high limit switch automatically resets when the temperature falls below 140 degrees Fahrenheit, providing an essential safety mechanism to prevent overheating. By incorporating this component into your heating system, you ensure reliable regulation of maximum temperature limits, enhancing the safety, performance, and longevity of your Low NOx heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEssential Safety Mechanism:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically resets when the temperature falls below 140 degrees Fahrenheit, preventing overheating and ensuring safe operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDesigned for Low NOx Heaters:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically engineered for Low NOx heaters, offering tailored safety and performance benefits.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eReliable Temperature Regulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides reliable regulation of maximum temperature limits, crucial for maintaining system integrity and performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances Longevity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e By incorporating this switch, you enhance the longevity and durability of your heating system, reducing the risk of damage due to excessive heat.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eImproves Safety and Performance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Boosts the overall safety and performance of your heater, ensuring it operates efficiently and effectively throughout its lifespan.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Low Nox Heaters: \u003c\/span\u003e\u003c\/strong\u003e207A, 267A, 337A, 407A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This high limit may be compatible with your heater, please refer to your systems owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_High_Limit_140F_Auto_Reset_For_Low_Nox_Heaters_600893B_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732747824\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599553073443,"sku":"600893B","price":30.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_High_Limit_140F_Auto_Reset_For_Low_Nox_Heaters_600893B_Wholesale_Pool_Mart_1.jpg?v=1738618970"},{"product_id":"raypak-high-limit-135f-auto-reset-for-low-nox-heaters-600892b","title":"Raypak High Limit 135F Auto Reset For Low Nox Heaters | 600892B","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe OEM Raypak High Limit 135F Auto Reset, model 600892B, is specifically designed for Low NOx heaters to ensure safe and efficient operation. This high limit switch automatically resets when the temperature falls below 135 degrees Fahrenheit, providing an essential safety mechanism to prevent overheating. By incorporating this component into your heating system, you ensure reliable regulation of maximum temperature limits, enhancing the safety, performance, and longevity of your Low NOx heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEssential Safety Mechanism:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically resets when the temperature falls below 135 degrees Fahrenheit, preventing overheating and ensuring safe operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDesigned for Low NOx Heaters:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically engineered for Low NOx heaters, offering tailored safety and performance benefits.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eReliable Temperature Regulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides reliable regulation of maximum temperature limits, crucial for maintaining system integrity and performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances Longevity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e By incorporating this switch, you enhance the longevity and durability of your heating system, reducing the risk of damage due to excessive heat.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eImproves Safety and Performance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Boosts the overall safety and performance of your heater, ensuring it operates efficiently and effectively throughout its lifespan.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Low Nox Heaters: \u003c\/span\u003e\u003c\/strong\u003e207A, 267A, 337A, 407A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This high limit may be compatible with your heater, please refer to your systems owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_High_Limit_135F_Auto_Reset_For_Low_Nox_Heaters_600892B_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732747771\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599555760419,"sku":"600892B","price":28.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_High_Limit_135F_Auto_Reset_For_Low_Nox_Heaters_600892B_Wholesale_Pool_Mart_1.jpg?v=1738618959"},{"product_id":"jandy-igniter-kit-for-jxi-heaters-r0457502","title":"Jandy R0457502 Igniter Kit | JXi Heaters","description":"\u003cp data-start=\"1658\" data-end=\"2174\" class=\"\"\u003eOEM Jandy Igniter Kit R0457502 is an essential ignition component specifically engineered for use with Jandy JXI pool and spa heaters. It ensures fast and reliable ignition, helping your heater maintain steady performance and consistent water temperature. Built for durability, this OEM kit withstands the demands of frequent cycling and contributes to extended heater life. Whether for routine replacement or troubleshooting issues, this kit is a key element in keeping your heating system dependable and efficient.\u003c\/p\u003e\n\u003ch3 data-start=\"2176\" data-end=\"2190\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2192\" data-end=\"2858\"\u003e\n\u003cli data-start=\"2192\" data-end=\"2318\" class=\"\"\u003e\n\u003cp data-start=\"2194\" data-end=\"2318\" class=\"\"\u003e\u003cstrong data-start=\"2194\" data-end=\"2223\"\u003eReliable Heater Ignition:\u003c\/strong\u003e Provides stable ignition to ensure your JXI heater lights consistently and operates smoothly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2319\" data-end=\"2455\" class=\"\"\u003e\n\u003cp data-start=\"2321\" data-end=\"2455\" class=\"\"\u003e\u003cstrong data-start=\"2321\" data-end=\"2345\"\u003eBuilt for Heavy Use:\u003c\/strong\u003e Constructed to endure high-heat environments, maintaining dependable performance even after repeated cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2456\" data-end=\"2590\" class=\"\"\u003e\n\u003cp data-start=\"2458\" data-end=\"2590\" class=\"\"\u003e\u003cstrong data-start=\"2458\" data-end=\"2488\"\u003eFast Temperature Recovery:\u003c\/strong\u003e Helps your system ignite quickly, reducing delays in heating and maintaining ideal water conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2591\" data-end=\"2728\" class=\"\"\u003e\n\u003cp data-start=\"2593\" data-end=\"2728\" class=\"\"\u003e\u003cstrong data-start=\"2593\" data-end=\"2618\"\u003eBoosts Unit Lifespan:\u003c\/strong\u003e Contributes to the overall durability and longevity of your heater by supporting clean and efficient starts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2729\" data-end=\"2858\" class=\"\"\u003e\n\u003cp data-start=\"2731\" data-end=\"2858\" class=\"\"\u003e\u003cstrong data-start=\"2731\" data-end=\"2762\"\u003eDependable Heating Results:\u003c\/strong\u003e Keeps your pool or spa heated when needed, ensuring reliable comfort and year-round usability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eJandy Igniter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eGasket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eNuts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eWashers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eStar Washers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eJandy JXI Heater Models: \u003c\/span\u003e\u003c\/strong\u003eJXI400N, JXI400NK, JXI400NN, JXI260N, JXI260NK, JXI200N, JXI200NK, JXI400NC, JXI260NC Natural and JXI400P, JXI400PN, JXI400PK, JXI260P, JXI260PK, JXI200P, JXI200PK, JXI400PC, JXI260PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1788\" data-end=\"1807\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1809\" data-end=\"1871\" class=\"\"\u003eR0457502 Igniter Kit – Jandy JXI Heater Ignition Assembly\u003c\/h2\u003e\n\u003ch4 data-start=\"1872\" data-end=\"1930\" class=\"\"\u003egreat local pricing on Jandy R0457502 ignition kits\u003c\/h4\u003e\n\u003ch4 data-start=\"1931\" data-end=\"1998\" class=\"\"\u003eincludes OEM igniter, seal gasket, and all required hardware\u003c\/h4\u003e\n\u003ch4 data-start=\"1999\" data-end=\"2064\" class=\"\"\u003eused by local pros for JXI heater ignition troubleshooting\u003c\/h4\u003e\n\u003ch4 data-start=\"2065\" data-end=\"2127\" class=\"\"\u003efits most Jandy JXI models: JXI400PN, JXI200PK, JXI260P\u003c\/h4\u003e\n\u003ch4 data-start=\"2128\" data-end=\"2186\" class=\"\"\u003eR0457502 ensures fast heat-up without startup delay\u003c\/h4\u003e\n\u003ch2 data-start=\"2188\" data-end=\"2256\" class=\"\"\u003eJandy Heater Igniter Replacement R0457502 – Propane\/Natural Gas\u003c\/h2\u003e\n\u003ch4 data-start=\"2257\" data-end=\"2326\" class=\"\"\u003ereliable performance in both commercial and residential setups\u003c\/h4\u003e\n\u003ch4 data-start=\"2327\" data-end=\"2385\" class=\"\"\u003efix JXI200, JXI260, JXI400 models with R0457502 kit\u003c\/h4\u003e\n\u003ch4 data-start=\"2386\" data-end=\"2444\" class=\"\"\u003elocal inventory available for same-day repair calls\u003c\/h4\u003e\n\u003ch4 data-start=\"2445\" data-end=\"2504\" class=\"\"\u003eimprove heat reliability and safety with OEM igniter\u003c\/h4\u003e\n\u003ch4 data-start=\"2505\" data-end=\"2563\" class=\"\"\u003esupports ignition sequence and burner flame control\u003c\/h4\u003e\n\u003ch2 data-start=\"2565\" data-end=\"2627\" class=\"\"\u003eJXI Heater Repair Kit R0457502 – For Long-Term Efficiency\u003c\/h2\u003e\n\u003ch4 data-start=\"2628\" data-end=\"2690\" class=\"\"\u003epart R0457502 helps extend heater life and cut downtime\u003c\/h4\u003e\n\u003ch4 data-start=\"2691\" data-end=\"2751\" class=\"\"\u003emaintain energy efficiency with proper ignition parts\u003c\/h4\u003e\n\u003ch4 data-start=\"2752\" data-end=\"2807\" class=\"\"\u003eessential service kit for yearly heater tune-ups\u003c\/h4\u003e\n\u003ch4 data-start=\"2808\" data-end=\"2869\" class=\"\"\u003ecompatible with JXI400PC, JXI400NC, and similar models\u003c\/h4\u003e\n\u003ch4 data-start=\"2870\" data-end=\"2925\" class=\"\"\u003elocal pickup available for contractors and techs\u003c\/h4\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Igniter_Kit_For_JXI_Heaters_R0457502_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732745975\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50599569391907,"sku":"R0457502","price":43.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Igniter_Kit_For_JXI_Heaters_R0457502_Wholesale_Pool_Mart_1.jpg?v=1738618889"},{"product_id":"jandy-high-limit-temperature-sensor-kit-for-jxi-heaters-r0592300","title":"Jandy R0592300 Temp Sensor Kit | High Limit | JXi Heaters","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003eOEM Jandy High Limit Temperature Sensor Kit R0592300 is a vital safety feature for JXI model pool heaters, designed to stop overheating before it causes damage. It includes two factory-set sensors—one positioned at the heat exchanger’s first pass (135°F) and another at the outlet (150°F)—to continuously monitor temperature levels. When either limit is reached, the gas valve shuts off automatically to stop combustion. This OEM sensor kit ensures your heater operates safely and protects system components from thermal stress and failure.\u003c\/p\u003e\n\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e To identify the correct part, you will need to know the model number, serial number and type of gas when applicable. This information can be found on the rating plate sticker, which is located inside the heater on the outside of the combustion chamber.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect vent for obstructions or blockages.\u003c\/li\u003e\n\u003cli\u003eIndoor installations, check vent pipe for bird, insect or rodent activity that could cause a blockage. \u003c\/li\u003e\n\u003cli\u003eReplace switches. \u003c\/li\u003e\n\u003cli\u003eRefer to qualified service personnel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2303\" data-end=\"2317\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2319\" data-end=\"3006\"\u003e\n\u003cli data-start=\"2319\" data-end=\"2460\" class=\"\"\u003e\n\u003cp data-start=\"2321\" data-end=\"2460\" class=\"\"\u003e\u003cstrong data-start=\"2321\" data-end=\"2359\"\u003eSafety-Driven Temperature Control:\u003c\/strong\u003e Detects high water temperatures and prevents system overheat by automatically disabling combustion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2461\" data-end=\"2602\" class=\"\"\u003e\n\u003cp data-start=\"2463\" data-end=\"2602\" class=\"\"\u003e\u003cstrong data-start=\"2463\" data-end=\"2494\"\u003ePrecision Sensor Setpoints:\u003c\/strong\u003e Activates at 135°F and 150°F through two strategically located sensors for layered temperature protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2603\" data-end=\"2745\" class=\"\"\u003e\n\u003cp data-start=\"2605\" data-end=\"2745\" class=\"\"\u003e\u003cstrong data-start=\"2605\" data-end=\"2638\"\u003eAutomatic Gas Valve Shutdown:\u003c\/strong\u003e Immediately closes the valve when unsafe heat levels are detected, maintaining safe operation conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2746\" data-end=\"2874\" class=\"\"\u003e\n\u003cp data-start=\"2748\" data-end=\"2874\" class=\"\"\u003e\u003cstrong data-start=\"2748\" data-end=\"2775\"\u003eExtends Equipment Life:\u003c\/strong\u003e Helps prevent long-term wear or failure due to heat-related stress, supporting system durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2875\" data-end=\"3006\" class=\"\"\u003e\n\u003cp data-start=\"2877\" data-end=\"3006\" class=\"\"\u003e\u003cstrong data-start=\"2877\" data-end=\"2902\"\u003eMade for JXI Heaters:\u003c\/strong\u003e OEM replacement kit designed for perfect integration with Jandy JXI models for safety and reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eJandy JXi Heater Models: \u003c\/span\u003e\u003c\/strong\u003eJXi200N, JXi200NK, JXi200P, JXi200PK, JXi260N, JXi260NK, JXi260P, JXi260PK, JXi400N, JXi400NK, JXi400NN, JXi400P, JXi400PK, JXi400PN, JXi260NC, JXi260PC, JXi400NC, JXi400PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1869\" data-end=\"1888\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1890\" data-end=\"1959\" class=\"\"\u003eR0592300 Safety Sensor Kit – Jandy JXI Heater Temperature Switch\u003c\/h2\u003e\n\u003ch4 data-start=\"1960\" data-end=\"2027\" class=\"\"\u003elocal pool pros rely on part R0592300 for JXI sensor repairs\u003c\/h4\u003e\n\u003ch4 data-start=\"2028\" data-end=\"2094\" class=\"\"\u003ebest local pricing on OEM Jandy dual high limit sensor kits\u003c\/h4\u003e\n\u003ch4 data-start=\"2095\" data-end=\"2155\" class=\"\"\u003eR0592300 protects JXI heater from overheating failure\u003c\/h4\u003e\n\u003ch4 data-start=\"2156\" data-end=\"2213\" class=\"\"\u003ecompatible with JXi200N, JXi400PN, JXi260PK models\u003c\/h4\u003e\n\u003ch4 data-start=\"2214\" data-end=\"2279\" class=\"\"\u003eincludes sensors for exchanger first pass and outlet temps\u003c\/h4\u003e\n\u003ch2 data-start=\"2281\" data-end=\"2349\" class=\"\"\u003eJandy Heater Protection R0592300 – Automatic Shutoff Sensor Kit\u003c\/h2\u003e\n\u003ch4 data-start=\"2350\" data-end=\"2417\" class=\"\"\u003eprevents overheating by stopping combustion at 135°F \u0026amp; 150°F\u003c\/h4\u003e\n\u003ch4 data-start=\"2418\" data-end=\"2478\" class=\"\"\u003eR0592300 used in both natural and propane JXI heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"2479\" data-end=\"2539\" class=\"\"\u003estop safety lockout codes with OEM sensor replacement\u003c\/h4\u003e\n\u003ch4 data-start=\"2540\" data-end=\"2594\" class=\"\"\u003eR0592300 part number used by local repair techs\u003c\/h4\u003e\n\u003ch4 data-start=\"2595\" data-end=\"2654\" class=\"\"\u003ehelps maintain heat exchanger performance and safety\u003c\/h4\u003e\n\u003ch2 data-start=\"2656\" data-end=\"2726\" class=\"\"\u003eHigh Temperature Sensor Switches R0592300 – For Gas Heater Safety\u003c\/h2\u003e\n\u003ch4 data-start=\"2727\" data-end=\"2791\" class=\"\"\u003einstall R0592300 during routine heater service or tune-up\u003c\/h4\u003e\n\u003ch4 data-start=\"2792\" data-end=\"2850\" class=\"\"\u003efits JXi400NC, JXi260NC, JXi400NN natural gas units\u003c\/h4\u003e\n\u003ch4 data-start=\"2851\" data-end=\"2908\" class=\"\"\u003emaintain code compliance with Jandy sensor upgrade\u003c\/h4\u003e\n\u003ch4 data-start=\"2909\" data-end=\"2973\" class=\"\"\u003epart R0592300 improves long-term reliability of JXI units\u003c\/h4\u003e\n\u003ch4 data-start=\"2974\" data-end=\"3029\" class=\"\"\u003estocked locally for fast access by professionals\u003c\/h4\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_High_Limit_Temperature_Sensor_Kit_For_JXI_Heaters_R0592300_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732745868\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50599572275491,"sku":"R0592300","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_High_Limit_Temperature_Sensor_Kit_For_JXI_Heaters_R0592300_Wholesale_Pool_Mart_1.jpg?v=1738618874"},{"product_id":"jandy-air-pressure-switch-for-jxi-and-lxi-heaters-r0456400","title":"Jandy R0456400 Air Pressure Switch | For JXi and LXi Heaters","description":"\u003cp data-start=\"1693\" data-end=\"2201\" class=\"\"\u003eOEM Jandy Air Pressure Switch R0456400 is a precision safety device designed for use in Jandy JXI and LXI pool and spa heaters. It monitors the air pressure within the unit and ensures that ignition only occurs when sufficient airflow is present. This function is crucial for maintaining heater safety and efficiency. Built to last in harsh conditions, the switch helps prevent potential heater damage and supports long-term performance, making it a vital part of your heating system’s operational integrity.\u003c\/p\u003e\n\u003ch3 data-start=\"2203\" data-end=\"2217\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2219\" data-end=\"2893\"\u003e\n\u003cli data-start=\"2219\" data-end=\"2361\" class=\"\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2361\" class=\"\"\u003e\u003cstrong data-start=\"2221\" data-end=\"2252\"\u003eDesigned for Safe Ignition:\u003c\/strong\u003e Allows the heater to activate only when proper internal air pressure is detected, preventing unsafe starts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2362\" data-end=\"2488\" class=\"\"\u003e\n\u003cp data-start=\"2364\" data-end=\"2488\" class=\"\"\u003e\u003cstrong data-start=\"2364\" data-end=\"2395\"\u003eMade for JXI and LXI Units:\u003c\/strong\u003e Compatible across multiple Jandy heater models for flexible replacement and dependable fit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2489\" data-end=\"2622\" class=\"\"\u003e\n\u003cp data-start=\"2491\" data-end=\"2622\" class=\"\"\u003e\u003cstrong data-start=\"2491\" data-end=\"2521\"\u003ePrevents Operating Errors:\u003c\/strong\u003e Helps avoid damage or performance issues by blocking heater function under poor airflow conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2623\" data-end=\"2747\" class=\"\"\u003e\n\u003cp data-start=\"2625\" data-end=\"2747\" class=\"\"\u003e\u003cstrong data-start=\"2625\" data-end=\"2645\"\u003eBuilt to Endure:\u003c\/strong\u003e Uses high-quality, heat-resistant materials capable of withstanding the demands of heater operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2748\" data-end=\"2893\" class=\"\"\u003e\n\u003cp data-start=\"2750\" data-end=\"2893\" class=\"\"\u003e\u003cstrong data-start=\"2750\" data-end=\"2785\"\u003eSupports Long-Term Reliability:\u003c\/strong\u003e Protects heater components by preventing activation during unsafe pressure levels, reducing service needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1885\" data-end=\"1904\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1906\" data-end=\"1976\" class=\"\"\u003eR0456400 Heater Air Pressure Switch – For JXI \u0026amp; LXI Compatibility\u003c\/h2\u003e\n\u003ch4 data-start=\"1977\" data-end=\"2048\" class=\"\"\u003eget local pricing on part R0456400 for heater airflow protection\u003c\/h4\u003e\n\u003ch4 data-start=\"2049\" data-end=\"2117\" class=\"\"\u003eswitch works with Jandy LXI400PC, LXI250NS, JXI200P, and more\u003c\/h4\u003e\n\u003ch4 data-start=\"2118\" data-end=\"2188\" class=\"\"\u003emaintain heating safety with reliable pressure switch detection\u003c\/h4\u003e\n\u003ch4 data-start=\"2189\" data-end=\"2250\" class=\"\"\u003eR0456400 includes hose and screws for complete install\u003c\/h4\u003e\n\u003ch4 data-start=\"2251\" data-end=\"2307\" class=\"\"\u003eused by local pros for heater airflow diagnostics\u003c\/h4\u003e\n\u003ch2 data-start=\"2309\" data-end=\"2371\" class=\"\"\u003eJandy R0456400 Pressure Sensor – For Safe Heater Ignition\u003c\/h2\u003e\n\u003ch4 data-start=\"2372\" data-end=\"2438\" class=\"\"\u003etriggers heater shutdown if airflow is below safe threshold\u003c\/h4\u003e\n\u003ch4 data-start=\"2439\" data-end=\"2497\" class=\"\"\u003efits both natural gas and propane pool heater units\u003c\/h4\u003e\n\u003ch4 data-start=\"2498\" data-end=\"2559\" class=\"\"\u003ereliable solution for JXI and LXI airflow fault errors\u003c\/h4\u003e\n\u003ch4 data-start=\"2560\" data-end=\"2627\" class=\"\"\u003eR0456400 helps extend heater life by preventing false starts\u003c\/h4\u003e\n\u003ch4 data-start=\"2628\" data-end=\"2687\" class=\"\"\u003einstall locally to restore stable combustion control\u003c\/h4\u003e\n\u003ch2 data-start=\"2689\" data-end=\"2754\" class=\"\"\u003eAirflow Control Switch R0456400 – Jandy Heater Safety Device\u003c\/h2\u003e\n\u003ch4 data-start=\"2755\" data-end=\"2828\" class=\"\"\u003edesigned for accurate airflow sensing in closed combustion systems\u003c\/h4\u003e\n\u003ch4 data-start=\"2829\" data-end=\"2893\" class=\"\"\u003efits popular models like JXI400PK, LXI250NC, and JXI260PC\u003c\/h4\u003e\n\u003ch4 data-start=\"2894\" data-end=\"2950\" class=\"\"\u003eprotects burners and flue from improper operation\u003c\/h4\u003e\n\u003ch4 data-start=\"2951\" data-end=\"3017\" class=\"\"\u003elocal availability for service techs and pool professionals\u003c\/h4\u003e\n\u003ch4 data-start=\"3018\" data-end=\"3082\" class=\"\"\u003eOEM design trusted for heater rebuild and inspection jobs\u003c\/h4\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50599584530723,"sku":"R0456400","price":129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Air_Pressure_Switch_For_JXI_and_LXI_Heaters_R0456400_Wholesale_Pool_Mart_1.jpg?v=1738618810"},{"product_id":"jandy-pressure-switch-for-jxi-heaters-r0457001","title":"Jandy R0457001 Pressure Switch | For JXi Heaters","description":"\u003cp data-start=\"159\" data-end=\"739\" class=\"\"\u003eOEM Jandy Pressure Switch R0457001 is engineered for precise use with JXI Heaters, serving as a critical control component that monitors water pressure levels inside the unit. It helps maintain safe and effective operation by triggering the heater on or off in response to pressure conditions. Built from durable materials, this switch offers long-term reliability and safeguards your system from potential damage caused by incorrect flow or pressure. With its easy-to-install design, the R0457001 supports consistent heater performance and contributes to extended equipment life.\u003c\/p\u003e\n\u003ch3 data-start=\"741\" data-end=\"755\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"756\" data-end=\"1358\"\u003e\n\u003cli data-start=\"756\" data-end=\"881\" class=\"\"\u003e\n\u003cp data-start=\"758\" data-end=\"881\" class=\"\"\u003e\u003cstrong data-start=\"758\" data-end=\"789\"\u003eCustom Fit for JXI Heaters:\u003c\/strong\u003e Designed specifically to work seamlessly with JXI models for accurate pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"882\" data-end=\"1004\" class=\"\"\u003e\n\u003cp data-start=\"884\" data-end=\"1004\" class=\"\"\u003e\u003cstrong data-start=\"884\" data-end=\"911\"\u003eEnsures Safe Operation:\u003c\/strong\u003e Activates or shuts off the heater based on internal pressure, preventing unsafe conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1005\" data-end=\"1123\" class=\"\"\u003e\n\u003cp data-start=\"1007\" data-end=\"1123\" class=\"\"\u003e\u003cstrong data-start=\"1007\" data-end=\"1034\"\u003eReliable Build Quality:\u003c\/strong\u003e Manufactured with high-grade materials to endure demanding pool environments over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1124\" data-end=\"1239\" class=\"\"\u003e\n\u003cp data-start=\"1126\" data-end=\"1239\" class=\"\"\u003e\u003cstrong data-start=\"1126\" data-end=\"1159\"\u003eProtects Against Flow Issues:\u003c\/strong\u003e Prevents heater damage caused by abnormal water flow or inconsistent pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1240\" data-end=\"1358\" class=\"\"\u003e\n\u003cp data-start=\"1242\" data-end=\"1358\" class=\"\"\u003e\u003cstrong data-start=\"1242\" data-end=\"1265\"\u003eQuick Installation:\u003c\/strong\u003e Simple to install and maintain, making it a key part of reliable heater system performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eJandy JXI Heater Models: \u003c\/span\u003e\u003c\/strong\u003eJXI400N, JXI400NK, JXI400NN, JXI260N, JXI260NK, JXI200N, JXI200NK Natural and JXI400P, JXI400PN, JXI400PK, JXI260P, JXI260PK, JXI200P, JXI200PK\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1372\" data-end=\"1391\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1393\" data-end=\"1449\" class=\"\"\u003eLocal Availability – Jandy R0457001 Pressure Switch\u003c\/h2\u003e\n\u003ch4 data-start=\"1450\" data-end=\"1512\" class=\"\"\u003epick up R0457001 locally for JXI heater pressure issues\u003c\/h4\u003e\n\u003ch4 data-start=\"1513\" data-end=\"1577\" class=\"\"\u003eR0457001 available with great local pricing for pool pros\u003c\/h4\u003e\n\u003ch4 data-start=\"1578\" data-end=\"1640\" class=\"\"\u003epart R0457001 used in JXI200P, JXI400P, JXI260N heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1641\" data-end=\"1705\" class=\"\"\u003ereplace Jandy JXI heater pressure switch R0457001 on site\u003c\/h4\u003e\n\u003ch4 data-start=\"1706\" data-end=\"1767\" class=\"\"\u003ebuy R0457001 for local maintenance or service installs\u003c\/h4\u003e\n\u003ch2 data-start=\"1769\" data-end=\"1825\" class=\"\"\u003eR0457001 Pressure Switch Fits All JXI Heater Models\u003c\/h2\u003e\n\u003ch4 data-start=\"1826\" data-end=\"1895\" class=\"\"\u003eR0457001 pressure switch compatible with JXI400PN and JXI260PK\u003c\/h4\u003e\n\u003ch4 data-start=\"1896\" data-end=\"1957\" class=\"\"\u003efits natural gas and propane JXI heaters like JXI200NK\u003c\/h4\u003e\n\u003ch4 data-start=\"1958\" data-end=\"2031\" class=\"\"\u003epressure sensor R0457001 ideal for JXI diagnostics and flow issues\u003c\/h4\u003e\n\u003ch4 data-start=\"2032\" data-end=\"2102\" class=\"\"\u003eJandy heater pressure switch R0457001 fits all major JXI models\u003c\/h4\u003e\n\u003ch4 data-start=\"2103\" data-end=\"2157\" class=\"\"\u003eR0457001 replacement available for local pickup\u003c\/h4\u003e\n\u003ch2 data-start=\"2159\" data-end=\"2207\" class=\"\"\u003eOEM Jandy R0457001 – Reliable Heater Switch\u003c\/h2\u003e\n\u003ch4 data-start=\"2208\" data-end=\"2276\" class=\"\"\u003eR0457001 for Jandy JXI heater water flow and pressure control\u003c\/h4\u003e\n\u003ch4 data-start=\"2277\" data-end=\"2340\" class=\"\"\u003euse R0457001 for JXI260NK JXI400NK JXI200P compatibility\u003c\/h4\u003e\n\u003ch4 data-start=\"2341\" data-end=\"2409\" class=\"\"\u003eR0457001 pressure switch replacement part for local customers\u003c\/h4\u003e\n\u003ch4 data-start=\"2410\" data-end=\"2473\" class=\"\"\u003egreat pricing available on R0457001 at local pool supply\u003c\/h4\u003e\n\u003ch4 data-start=\"2474\" data-end=\"2537\" class=\"\"\u003ebuy pressure switch R0457001 for full JXI series heaters\u003c\/h4\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Pressure_Switch_For_JXI_Heaters_R0457001_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732745567\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50599599374627,"sku":"R0457001","price":46.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Pressure_Switch_For_JXI_Heaters_R0457001_Wholesale_Pool_Mart_1.jpg?v=1738618748"},{"product_id":"raypak-pressure-switch-for-low-nox-heaters-006737f","title":"Raypak Pressure Switch For Low Nox Heaters | 006737F","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe OEM Raypak Pressure Switch, model 006737F, is engineered for use with Low Nox Heaters, ensuring safe and efficient operation. This pressure switch monitors the water pressure within the heater, automatically shutting it down if pressures fall outside the optimal range to prevent potential damage and ensure user safety. Constructed from robust materials, the 006737F is built for long-lasting performance and reliability. Easy to install and replace, it is essential for maintaining the optimal function and safety of Low Nox Heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\u003cspan\u003eDesigned specifically for use with Low Nox Heaters, ensuring safe and efficient operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eMonitors Water Pressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuously monitors water pressure within the heater and automatically shuts it down if pressures fall outside the optimal range, preventing potential damage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances Safety:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Plays a crucial role in ensuring user safety by preventing the heater from operating under unsafe pressure conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eRobust and Reliable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Made from durable, high-quality materials for long-lasting performance and reliability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEasy to Install and Replace:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Simplifies maintenance with an easy installation and replacement process, essential for maintaining the optimal function and safety of Low Nox Heaters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Digital Low Nox Heater Models:\u003c\/span\u003e\u003c\/strong\u003e 207A, 267A, 337A, 407A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRaypak Heater Models: \u003c\/span\u003e\u003c\/strong\u003eR185A, R265A, R335A, R405A, 264A, 404A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This Pressure Switch may be compatible with your heater, please refer to your systems owners manual to ensure compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Pressure_Switch_For_Low_Nox_Heaters_006737F_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732747523\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599623131427,"sku":"006737F","price":49.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Pressure_Switch_For_Low_Nox_Heaters_006737F_Wholesale_Pool_Mart_1.jpg?v=1738618615"},{"product_id":"raypak-gas-valve-with-gas-line-half-for-avia-heaters-018870f","title":"Raypak Gas Valve With Gas Line Half For AVIA Heaters | 018870F","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe Raypak Gas Valve with Gas Line Half, model 018870F, is designed for AVIA heaters, providing a crucial component for the safe and efficient operation of your heating system. This gas valve ensures precise control of gas flow, contributing to consistent and reliable heater performance. Made from high-quality materials for durability, the 018870F is easy to install and essential for maintaining the optimal functionality of your AVIA heater. Its precision engineering ensures your heating system operates safely and effectively, enhancing the overall efficiency of your pool or spa.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePrecise Gas Flow Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for AVIA heaters, it ensures precise control of gas flow for consistent and reliable heater performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eSafe and Efficient Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Contributes to the safe and efficient operation of your heating system, enhancing overall efficiency.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-Quality and Durable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Made from high-quality materials, ensuring durability and long-lasting performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEasy Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Simple to install, making it essential for maintaining the optimal functionality of your AVIA heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePrecision Engineering:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered with precision to ensure your heating system operates safely and effectively, ideal for both pool and spa use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with Raypak AVIA Heater Models: 404\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Gas_Valve_With_Gas_Line_Half_For_AVIA_Heaters_018870F_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732746952\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50599641481507,"sku":"018870F","price":229.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_Gas_Valve_With_Gas_Line_Half_For_AVIA_Heaters_018870F_Wholesale_Pool_Mart_1.jpg?v=1738618526"},{"product_id":"hayward-water-pressure-switch-for-fd-heaters-fdxlwps1931","title":"Hayward FDXLWPS1931 Water Pressure Switch | FD Heaters","description":"\u003cp class=\"\" data-end=\"2235\" data-start=\"1603\"\u003eOEM Hayward FDXLWPS1931 Water Pressure Switch is engineered for use in Universal H-Series Low NOx and HDF400 pool heaters, where it safeguards against low water flow that can lead to overheating and system damage. This pressure-sensitive switch prevents the heater from igniting unless adequate water pressure is detected, ensuring safe and efficient operation. Constructed from durable, high-quality materials, it provides long-lasting reliability in demanding pool environments. Whether for preventative maintenance or urgent repairs, this switch is a key component in maintaining your heater’s overall performance and protection.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"2253\" data-start=\"2237\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-end=\"2961\" data-start=\"2254\"\u003e\n\u003cli class=\"\" data-end=\"2401\" data-start=\"2254\"\u003e\n\u003cp class=\"\" data-end=\"2401\" data-start=\"2256\"\u003e\u003cstrong data-end=\"2301\" data-start=\"2256\"\u003eCompatible with Universal and HDF Models:\u003c\/strong\u003e OEM switch fits a wide range of Hayward Low NOx and HDF heaters for dependable system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2550\" data-start=\"2402\"\u003e\n\u003cp class=\"\" data-end=\"2550\" data-start=\"2404\"\u003e\u003cstrong data-end=\"2444\" data-start=\"2404\"\u003eProtects Against Low-Flow Operation:\u003c\/strong\u003e Automatically disables ignition when insufficient pressure is detected to prevent heat exchanger damage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2684\" data-start=\"2551\"\u003e\n\u003cp class=\"\" data-end=\"2684\" data-start=\"2553\"\u003e\u003cstrong data-end=\"2588\" data-start=\"2553\"\u003eEnhances Safety and Efficiency:\u003c\/strong\u003e Supports consistent heater operation by ensuring proper water flow during every heating cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2818\" data-start=\"2685\"\u003e\n\u003cp class=\"\" data-end=\"2818\" data-start=\"2687\"\u003e\u003cstrong data-end=\"2718\" data-start=\"2687\"\u003eLong-Lasting Build Quality:\u003c\/strong\u003e Crafted to resist corrosion and wear from pool chemicals, temperature changes, and continuous use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2961\" data-start=\"2819\"\u003e\n\u003cp class=\"\" data-end=\"2961\" data-start=\"2821\"\u003e\u003cstrong data-end=\"2867\" data-start=\"2821\"\u003eEssential for Reliable Heater Maintenance:\u003c\/strong\u003e Ideal replacement part for addressing flow-related issues and extending heater service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHayward H-Series Heaters Models:\u003c\/span\u003e\u003c\/strong\u003e H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, H500FD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward HDF Series Heater Models:\u003c\/strong\u003e HDF400\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Water_Pressure_Switch_For_FD_Heaters_FDXLWPS1931_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732741108\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50599670448419,"sku":"FDXLWPS1931","price":45.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Water_Pressure_Switch_For_FD_Heaters_FDXLWPS1931_Wholesale_Pool_Mart_1.jpg?v=1738618393"},{"product_id":"hayward-flame-sensor-for-universal-h-series-induced-draft-gas-heaters-idxlfls1930","title":"Hayward IDXLFLS1930 Flame Sensor | For H-Series Heaters","description":"\u003cp class=\"\" data-end=\"2156\" data-start=\"1551\"\u003eOEM Hayward IDXLFLS1930 Flame Sensor is an essential ignition safety device for Universal H-Series Induced Draft and Gas Heaters, providing real-time flame detection to ensure secure system operation. By verifying the presence of a flame during startup, the sensor allows proper combustion and signals shutdown if the flame is absent. Its durable construction supports reliable use in high-heat, high-moisture environments typical of pool equipment. Whether conducting routine service or addressing ignition issues, this OEM sensor is critical to maintaining the safety and efficiency of your pool heater.\u003c\/p\u003e\n\u003ch3 class=\"\" data-end=\"2174\" data-start=\"2158\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-end=\"2894\" data-start=\"2175\"\u003e\n\u003cli class=\"\" data-end=\"2324\" data-start=\"2175\"\u003e\n\u003cp class=\"\" data-end=\"2324\" data-start=\"2177\"\u003e\u003cstrong data-end=\"2221\" data-start=\"2177\"\u003eFits Universal H-Series and IDL2 Models:\u003c\/strong\u003e OEM flame sensor designed for seamless integration with Hayward heater models from H150FDN to H500FD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2455\" data-start=\"2325\"\u003e\n\u003cp class=\"\" data-end=\"2455\" data-start=\"2327\"\u003e\u003cstrong data-end=\"2360\" data-start=\"2327\"\u003eEnables Safe Heater Ignition:\u003c\/strong\u003e Detects flame presence at startup and ensures the burner is operating within safe parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2602\" data-start=\"2456\"\u003e\n\u003cp class=\"\" data-end=\"2602\" data-start=\"2458\"\u003e\u003cstrong data-end=\"2498\" data-start=\"2458\"\u003ePrevents Gas-Related Safety Hazards:\u003c\/strong\u003e Triggers system shutdown if no flame is detected, protecting against gas buildup or combustion errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2741\" data-start=\"2603\"\u003e\n\u003cp class=\"\" data-end=\"2741\" data-start=\"2605\"\u003e\u003cstrong data-end=\"2648\" data-start=\"2605\"\u003eBuilt to Withstand Poolside Conditions:\u003c\/strong\u003e Made from high-quality materials that resist corrosion, heat, and water exposure over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"2894\" data-start=\"2742\"\u003e\n\u003cp class=\"\" data-end=\"2894\" data-start=\"2744\"\u003e\u003cstrong data-end=\"2793\" data-start=\"2744\"\u003eIdeal for Preventive Service or Fault Repair:\u003c\/strong\u003e Restores reliable flame detection to resolve ignition faults and maintain heater safety compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHayward H-Series Heaters Models:\u003c\/span\u003e\u003c\/strong\u003e H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, H500FD\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e, H250IDL2, H350IDL2, H400IDL2.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1350\" data-end=\"1369\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1371\" data-end=\"1409\" class=\"\"\u003eSymptoms of a Faulty Flame Sensor\u003c\/h2\u003e\n\u003ch4 data-start=\"1410\" data-end=\"1458\" class=\"\"\u003eflame not detected but burner visibly lit\u003c\/h4\u003e\n\u003ch4 data-start=\"1459\" data-end=\"1513\" class=\"\"\u003ehayward heater lights then cuts off every cycle\u003c\/h4\u003e\n\u003ch4 data-start=\"1514\" data-end=\"1566\" class=\"\"\u003eerror code points to idxlfls1930 flame sensor\u003c\/h4\u003e\n\u003ch4 data-start=\"1567\" data-end=\"1615\" class=\"\"\u003etroubleshoot no ignition on h200fdn model\u003c\/h4\u003e\n\u003ch4 data-start=\"1616\" data-end=\"1669\" class=\"\"\u003eintermittent heating caused by worn sensor tip\u003c\/h4\u003e\n\u003ch2 data-start=\"1671\" data-end=\"1702\" class=\"\"\u003eSpecs and Local Price Info\u003c\/h2\u003e\n\u003ch4 data-start=\"1703\" data-end=\"1751\" class=\"\"\u003echeck local price for hayward idxlfls1930\u003c\/h4\u003e\n\u003ch4 data-start=\"1752\" data-end=\"1804\" class=\"\"\u003especs for flame sensor probe length and mount\u003c\/h4\u003e\n\u003ch4 data-start=\"1805\" data-end=\"1863\" class=\"\"\u003elocal stock of idxlfls1930 flame sensor for heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1864\" data-end=\"1919\" class=\"\"\u003esensor part number match for h-series heater fix\u003c\/h4\u003e\n\u003ch4 data-start=\"1920\" data-end=\"1979\" class=\"\"\u003ehow much resistance should hayward flame sensor read\u003c\/h4\u003e\n\u003ch2 data-start=\"1981\" data-end=\"2014\" class=\"\"\u003eConfirming Model Fit Locally\u003c\/h2\u003e\n\u003ch4 data-start=\"2015\" data-end=\"2072\" class=\"\"\u003econfirm idxlfls1930 works with h400fdn and h350fdp\u003c\/h4\u003e\n\u003ch4 data-start=\"2073\" data-end=\"2129\" class=\"\"\u003efind correct flame sensor for hayward pool heater\u003c\/h4\u003e\n\u003ch4 data-start=\"2130\" data-end=\"2182\" class=\"\"\u003ematch sensor model to heater version in store\u003c\/h4\u003e\n\u003ch4 data-start=\"2183\" data-end=\"2233\" class=\"\"\u003ecompatible with h250idl2 and h400idl2 units\u003c\/h4\u003e\n\u003ch4 data-start=\"2234\" data-end=\"2284\" class=\"\"\u003elocal guide to finding correct flame sensor\u003c\/h4\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Flame_Sensor_For_Universal_H-Series_Induced_Draft_Gas_Heaters_IDXLFLS1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732744212\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50599706755363,"sku":"IDXLFLS1930","price":76.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_Flame_Sensor_For_Universal_H-Series_Induced_Draft_Gas_Heaters_IDXLFLS1930_Wholesale_Pool_Mart_1.jpg?v=1737144197"},{"product_id":"hayward-high-limit-switch-kit-for-fd-h-series-low-nox-heaters-heaters-fdxlhli1930","title":"Hayward FDXLHLI1930 High Limit Kit | FD H-Series Heaters","description":"\u003cp data-start=\"1499\" data-end=\"2052\" class=\"\"\u003eOEM Hayward FDXLHLI1930 High Limit Kit is an essential protective component for FD H-Series Low NOx pool heaters, designed to shut off the system when excessive temperatures are detected. This feature safeguards critical heater parts and maintains proper operating conditions. Built for durability, the kit withstands high-heat exposure and provides consistent thermal regulation over extended use. Ideal for scheduled tune-ups or system fault repairs, it plays a key role in sustaining heater efficiency and ensuring safe operation season after season.\u003c\/p\u003e\n\u003ch3 data-start=\"2054\" data-end=\"2070\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2071\" data-end=\"2759\"\u003e\n\u003cli data-start=\"2071\" data-end=\"2210\" class=\"\"\u003e\n\u003cp data-start=\"2073\" data-end=\"2210\" class=\"\"\u003e\u003cstrong data-start=\"2073\" data-end=\"2118\"\u003eDesigned for FD H-Series Low NOx Heaters:\u003c\/strong\u003e OEM kit tailored to maintain thermal safety in Hayward models from H150FDN through H500FD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2211\" data-end=\"2350\" class=\"\"\u003e\n\u003cp data-start=\"2213\" data-end=\"2350\" class=\"\"\u003e\u003cstrong data-start=\"2213\" data-end=\"2258\"\u003eProtects Against Unsafe Temperature Rise:\u003c\/strong\u003e Automatically disengages the heating system when internal temperatures exceed safe levels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2351\" data-end=\"2492\" class=\"\"\u003e\n\u003cp data-start=\"2353\" data-end=\"2492\" class=\"\"\u003e\u003cstrong data-start=\"2353\" data-end=\"2399\"\u003eEngineered for Harsh Operating Conditions:\u003c\/strong\u003e Features heat-resistant materials built to survive high temperatures and moisture exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2493\" data-end=\"2623\" class=\"\"\u003e\n\u003cp data-start=\"2495\" data-end=\"2623\" class=\"\"\u003e\u003cstrong data-start=\"2495\" data-end=\"2537\"\u003eSupports Preventive Maintenance Goals:\u003c\/strong\u003e Easy to install during regular service to reduce the risk of future system failures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2624\" data-end=\"2759\" class=\"\"\u003e\n\u003cp data-start=\"2626\" data-end=\"2759\" class=\"\"\u003e\u003cstrong data-start=\"2626\" data-end=\"2670\"\u003eMaintains Safe and Consistent Operation:\u003c\/strong\u003e Helps ensure optimal heating output without compromising the unit’s internal integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHayward H-Series Heaters Models:\u003c\/span\u003e\u003c\/strong\u003e H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, H500FD\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1416\" data-end=\"1435\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1437\" data-end=\"1480\" class=\"\"\u003eIdentifying Faulty High Limit Symptoms\u003c\/h2\u003e\n\u003ch4 data-start=\"1481\" data-end=\"1535\" class=\"\"\u003eheater trips breaker or locks out at high temps\u003c\/h4\u003e\n\u003ch4 data-start=\"1536\" data-end=\"1584\" class=\"\"\u003esystem reset doesn’t fix overheat shutoff\u003c\/h4\u003e\n\u003ch4 data-start=\"1585\" data-end=\"1643\" class=\"\"\u003econtrol panel shows overheating without flame issue\u003c\/h4\u003e\n\u003ch4 data-start=\"1644\" data-end=\"1697\" class=\"\"\u003eheat exchanger gets too hot check limit switch\u003c\/h4\u003e\n\u003ch4 data-start=\"1698\" data-end=\"1751\" class=\"\"\u003eheater won’t restart fdxlhli1930 may be needed\u003c\/h4\u003e\n\u003ch2 data-start=\"1753\" data-end=\"1790\" class=\"\"\u003eKit Specs and Local Price Lookup\u003c\/h2\u003e\n\u003ch4 data-start=\"1791\" data-end=\"1849\" class=\"\"\u003echeck local price for fdxlhli1930 high limit switch\u003c\/h4\u003e\n\u003ch4 data-start=\"1850\" data-end=\"1907\" class=\"\"\u003eincludes both limit sensors for hayward fd heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1908\" data-end=\"1963\" class=\"\"\u003erugged temperature sensor for outdoor conditions\u003c\/h4\u003e\n\u003ch4 data-start=\"1964\" data-end=\"2018\" class=\"\"\u003ebuilt to withstand high temp pool heater cycles\u003c\/h4\u003e\n\u003ch4 data-start=\"2019\" data-end=\"2073\" class=\"\"\u003efind replacement overheat sensor at local store\u003c\/h4\u003e\n\u003ch2 data-start=\"2075\" data-end=\"2112\" class=\"\"\u003eConfirming Compatibility and Fit\u003c\/h2\u003e\n\u003ch4 data-start=\"2113\" data-end=\"2167\" class=\"\"\u003ewill fdxlhli1930 work with older h200fdn heater\u003c\/h4\u003e\n\u003ch4 data-start=\"2168\" data-end=\"2212\" class=\"\"\u003ecompatible with all fd low nox models\u003c\/h4\u003e\n\u003ch4 data-start=\"2213\" data-end=\"2272\" class=\"\"\u003elocal match for hayward h-series temperature shutoff\u003c\/h4\u003e\n\u003ch4 data-start=\"2273\" data-end=\"2328\" class=\"\"\u003everify your heater model before buying limit kit\u003c\/h4\u003e\n\u003ch4 data-start=\"2329\" data-end=\"2386\" class=\"\"\u003efits both indoor and outdoor h-series applications\u003c\/h4\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_High_Limit_Switch_Kit_For_FD_H-Series_Low_Nox_Heaters_Heaters_FDXLHLI1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732744659\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50599715307811,"sku":"FDXLHLI1930","price":68.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_High_Limit_Switch_Kit_For_FD_H-Series_Low_Nox_Heaters_Heaters_FDXLHLI1930_Wholesale_Pool_Mart_1.jpg?v=1736789156"},{"product_id":"hayward-fd-ignitor-for-universal-h-series-low-nox-heaters-fdxlign1930","title":"Hayward FDXLIGN1930 Ignitor | For H-Series FD Heaters","description":"\u003cp data-start=\"1506\" data-end=\"2109\" class=\"\"\u003eOEM Hayward FDXLIGN1930 Ignitor is a critical replacement part for Universal H-Series Low NOx and HDF400 pool heaters, delivering consistent ignition to start the combustion process. Designed with precision compatibility in mind, this high-performance ignitor ensures the heater fires reliably and operates at peak efficiency. Its rugged construction holds up to extreme temperatures and repeated use, making it ideal for both scheduled tune-ups and immediate repair needs. This component is essential for preserving heater reliability, ensuring your pool or spa remains comfortable and properly heated.\u003c\/p\u003e\n\u003ch3 data-start=\"2111\" data-end=\"2127\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2128\" data-end=\"2812\"\u003e\n\u003cli data-start=\"2128\" data-end=\"2271\" class=\"\"\u003e\n\u003cp data-start=\"2130\" data-end=\"2271\" class=\"\"\u003e\u003cstrong data-start=\"2130\" data-end=\"2180\"\u003eEngineered for Universal and HC-Series Models:\u003c\/strong\u003e Compatible with H150FDN through H500FD and HDF400 heaters for OEM-level ignition control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2272\" data-end=\"2399\" class=\"\"\u003e\n\u003cp data-start=\"2274\" data-end=\"2399\" class=\"\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2312\"\u003eIgnites Burner Quickly and Safely:\u003c\/strong\u003e Produces a stable spark to initiate combustion, minimizing startup errors and delays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2400\" data-end=\"2533\" class=\"\"\u003e\n\u003cp data-start=\"2402\" data-end=\"2533\" class=\"\"\u003e\u003cstrong data-start=\"2402\" data-end=\"2443\"\u003eHigh-Temperature-Resistant Materials:\u003c\/strong\u003e Built to endure thermal stress and poolside conditions without degrading in performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2534\" data-end=\"2668\" class=\"\"\u003e\n\u003cp data-start=\"2536\" data-end=\"2668\" class=\"\"\u003e\u003cstrong data-start=\"2536\" data-end=\"2573\"\u003eEssential for Service and Repair:\u003c\/strong\u003e Perfect for resolving ignition failures and maintaining system readiness during seasonal use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2669\" data-end=\"2812\" class=\"\"\u003e\n\u003cp data-start=\"2671\" data-end=\"2812\" class=\"\"\u003e\u003cstrong data-start=\"2671\" data-end=\"2709\"\u003eBoosts Overall Heater Reliability:\u003c\/strong\u003e Ensures consistent burner activation, helping maintain warm water conditions with minimal disruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHayward H-Series Heaters Models:\u003c\/span\u003e\u003c\/strong\u003e H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, H500FD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHayward HC-Series Heater Models: \u003c\/strong\u003eHDF400\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1329\" data-end=\"1348\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1350\" data-end=\"1383\" class=\"\"\u003eSigns of Ignitor Malfunction\u003c\/h2\u003e\n\u003ch4 data-start=\"1384\" data-end=\"1430\" class=\"\"\u003eheater not lighting after several tries\u003c\/h4\u003e\n\u003ch4 data-start=\"1431\" data-end=\"1469\" class=\"\"\u003eignitor tip blackened or broken\u003c\/h4\u003e\n\u003ch4 data-start=\"1470\" data-end=\"1520\" class=\"\"\u003eweak or no spark coming from heater ignitor\u003c\/h4\u003e\n\u003ch4 data-start=\"1521\" data-end=\"1572\" class=\"\"\u003elow voltage error could mean ignitor failure\u003c\/h4\u003e\n\u003ch4 data-start=\"1573\" data-end=\"1624\" class=\"\"\u003efix flame detection by replacing fdxlign1930\u003c\/h4\u003e\n\u003ch2 data-start=\"1626\" data-end=\"1664\" class=\"\"\u003eKit Details and Local Price Check\u003c\/h2\u003e\n\u003ch4 data-start=\"1665\" data-end=\"1722\" class=\"\"\u003echeck local pricing on hayward fdxlign1930 ignitor\u003c\/h4\u003e\n\u003ch4 data-start=\"1723\" data-end=\"1773\" class=\"\"\u003especs and wiring connector info for ignitor\u003c\/h4\u003e\n\u003ch4 data-start=\"1774\" data-end=\"1823\" class=\"\"\u003edoes fdxlign1930 include mounting hardware\u003c\/h4\u003e\n\u003ch4 data-start=\"1824\" data-end=\"1882\" class=\"\"\u003efind replacement ignitor for hayward heater near me\u003c\/h4\u003e\n\u003ch4 data-start=\"1883\" data-end=\"1937\" class=\"\"\u003edurable ignitor for outdoor heater environments\u003c\/h4\u003e\n\u003ch2 data-start=\"1939\" data-end=\"1969\" class=\"\"\u003eVerifying Fitment Locally\u003c\/h2\u003e\n\u003ch4 data-start=\"1970\" data-end=\"2024\" class=\"\"\u003efdxlign1930 replacement for 2023 h250fdp heater\u003c\/h4\u003e\n\u003ch4 data-start=\"2025\" data-end=\"2081\" class=\"\"\u003edoes this ignitor work with hc-series gas heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"2082\" data-end=\"2130\" class=\"\"\u003ematch part number to your current ignitor\u003c\/h4\u003e\n\u003ch4 data-start=\"2131\" data-end=\"2174\" class=\"\"\u003ewill this fit h400fdp or just hdf400\u003c\/h4\u003e\n\u003ch4 data-start=\"2175\" data-end=\"2229\" class=\"\"\u003everify heater compatibility before buying local\u003c\/h4\u003e\n\u003ch3\u003eDiagram\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_FD_Ignitor_For_Universal_H-Series_Low_Nox_Heaters_FDXLIGN1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732743942\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50599728742691,"sku":"FDXLIGN1930","price":106.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_FD_Ignitor_For_Universal_H-Series_Low_Nox_Heaters_FDXLIGN1930_Wholesale_Pool_Mart_1.jpg?v=1736789104"},{"product_id":"swimables-high-limit-switch-for-pentair-mastertemp-and-max-e-therm-heaters-42001-0063s-sw-41-063","title":"Swimables High Limit Switch for Pentair MasterTemp And Max-E-Therm Heaters | 42001-0063S | SW-41-063","description":"\u003cp\u003e\u003cspan\u003eThe Swimables Hi Limit Switch SW-41-063 is a safety switch used to detect when water temperature has exceeded a safe level (135°F) and immediately opens the heat exchanger out. When this fails, your system will typically show error code HLS. \u003c\/span\u003e\u003cspan\u003eThe Hi Limit Switch cannot be reset, it must be replaced. This Swimables Hi Limit Switch SW-41-063 is compatible with most Pentair MasterTemp and Sta-Rite Max-E-Therm Natural Gas Swimming Pool Heaters. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCritical Safety Feature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Activates by detecting unsafe water temperatures above 135°F, instantly preventing heat exchanger overload.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eError Code Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to display an HLS error code as a clear indicator of failure, necessitating a timely replacement.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eMandatory Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e As a non-resettable component, this Hi Limit Switch is built to be replaced, not repaired, ensuring ongoing safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eBroad Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible with a wide range of Pentair heaters, including MasterTemp and Sta-Rite Max-E-ThermNatural Gas models.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair Sta-Rite Max-E-Therm Heaters\u003c\/li\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentair ETI 400 Heaters\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_High_Limit_Switch_for_Pentair_MasterTemp_And_Max-E-Therm_Heaters_42001-0063S_SW-41-063_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732572354\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50599843594531,"sku":"SW-41-063","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_High_Limit_Switch_for_Pentair_MasterTemp_And_Max-E-Therm_Heaters_42001-0063S_SW-41-063_Wholesale_Pool_Mart_1.jpg?v=1738617625"},{"product_id":"swimables-thermistor-for-pentair-mastertemp-and-max-e-therm-heaters-42001-0053s-sw-41-053","title":"Swimables Thermistor for Pentair MasterTemp And Max-E-Therm Heaters | 42001-0053S | SW-41-053","description":"\u003cp\u003e\u003cspan\u003eThe Swimables Thermistor SW-41-053 is responsible for displaying the temperature on your control panel. Typically if the display reading is indicating a temperature that is too high then your thermistor needs to replaced. \u003c\/span\u003e\u003cspan\u003eThe Thermistor cannot be reset, it must be replaced. This Swimables Thermistor SW-41-053 is compatible with most Pentair MasterTemp, Sta-Rite Max-E-Therm and ETI 400 Natural Gas Swimming Pool Heaters. An electronic temperature sensing thermistor in the manifold adapter inlet controls the heater operation. When the inlet water temperature drops below the temperature set on the operating control, the burner controller supplies power to the combustion air blower through a series of safety interlocks\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCrucial Temperature Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Vital for accurately reflecting the water temperature on control panels, signaling when a replacement is needed for consistent monitoring.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eNon-Resettable Part:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This Swimables replacement thermistor guarantees a precise fit and function for specified Pentair heaters, necessitating replacement, not resetting, when faulty.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to integrate seamlessly with most Pentair MasterTemp, Sta-Rite Max-E-Therm, and ETI 400 Natural Gas Pool Heaters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eIntelligent Heating Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically regulates the heater operation through an electronic temperature-sensing mechanism, ensuring safety and efficiency.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair Sta-Rite Max-E-Therm Heaters\u003c\/li\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentair ETI 400 Heaters\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_Thermistor_for_Pentair_MasterTemp_And_Max-E-Therm_Heaters_42001-0053S_SW-41-053_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732637954\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Swimables","offers":[{"title":"Default Title","offer_id":50599850115363,"sku":"SW-41-053","price":26.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_Thermistor_for_Pentair_MasterTemp_And_Max-E-Therm_Heaters_42001-0053S_SW-41-053_Wholesale_Pool_Mart_1.jpg?v=1738617584"},{"product_id":"pentair-ignition-control-module-mastertemp-and-max-e-therm-heaters-42001-0052s-476223","title":"Pentair Ignition Control Module MasterTemp And Max-E-Therm Heaters | 42001-0052S | 476223","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe OEM Pentair Ignition Control Module, model 476223, formerly 42001-0052S, is a vital replacement part for MasterTemp and Max-E-Therm Heaters. This module is responsible for controlling the ignition process, ensuring your heater starts efficiently and operates reliably. Designed for compatibility with Pentair heaters, it offers an easy installation process and restores optimal functionality to your heating system. Constructed with premium materials, the 476223 Ignition Control Module delivers durability and long-term performance, making it an essential component for maintaining the efficiency and safety of your Pentair heating equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe Ignition Module is microprocessor based and operates on 24VAC supplied by the transformer. The control utilizes a microprocessor to continually and safely monitor, analyze, and control the proper operation of the gas flame holder. The module with the presence of the flame sensor, using flame rectification, allows the heater to operate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eVital Replacement Part:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for controlling the ignition process in MasterTemp and Max-E-Therm Heaters, ensuring efficient and reliable starts.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEasy Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for compatibility with Pentair heaters, allowing for a straightforward installation process to restore optimal functionality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eReliable Performance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ensures that your heating system operates reliably, maintaining the efficiency and safety of your equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Made with premium materials, this ignition control module offers long-term performance and durability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eMaintains Efficiency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Crucial for maintaining the overall efficiency and safety of your Pentair heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eIgnition Control Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(4) \u003c\/strong\u003eConnector Cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(2) \u003c\/strong\u003eScrews\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with most Pentair MasterTemp and Max-E-Therm Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Ignition_Control_Module_MasterTemp_And_Max-E-Therm_Heaters_42001-0052S_476223_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732736856\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50599865188643,"sku":"476223","price":268.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Ignition_Control_Module_MasterTemp_And_Max-E-Therm_Heaters_42001-0052S_476223_Wholesale_Pool_Mart_1.jpg?v=1738617475"},{"product_id":"swimables-igniter-with-gasket-kit-for-pentair-mastertemp-and-max-e-therm-heaters-77707-0054-sw-41-054","title":"Swimables Igniter With Gasket Kit For Pentair MasterTemp and Max-E-Therm Heaters | 77707-0054 | SW-41-054","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003eThe Swimables Igniter With Gasket Kit, model SW-41-054, is a crucial component for maintaining the reliable performance of MasterTemp and Max-E-Therm Heaters. This kit includes a high-quality igniter and a gasket, ensuring a secure fit and optimal ignition of your heater. Designed for easy installation, the kit helps restore your heater's functionality, providing quick and efficient ignition. Made from durable materials, both the igniter and gasket in this kit are built to withstand high temperatures and prolonged use, making it an essential part of your heater maintenance and repair toolkit. All MasterTemp heaters are designed with a direct ignition device, HSI (hot-surface ignition), which eliminates the need for a standing pilot. The MasterTemp heater requires an external power source (120\/240 VAC 60 Hz) to operate.\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCrucial Component:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for maintaining the reliable performance of MasterTemp and Max-E-Therm Heaters, ensuring consistent operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-Quality Components:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes a high-quality igniter and gasket, providing a secure fit and optimal ignition of your heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEasy Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for easy installation, allowing you to quickly restore your heater's functionality with efficient ignition.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Materials:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Both the igniter and gasket are made from durable materials, capable of withstanding high temperatures and prolonged use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEfficient Ignition System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e All MasterTemp heaters use a direct ignition device (HSI), eliminating the need for a standing pilot and requiring an external power source (120\/240 VAC 60 Hz).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e SW-41-054 Igniter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e SW-41-054 Igniter Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentair Sta-Rite Max-E-Therm Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_Igniter_With_Gasket_Kit_For_Pentair_MasterTemp_and_Max-E-Therm_Heaters_77707-0054_SW-41-054_Wholesale_Pool_Mart_diagram_65949ee9-7b7a-47a7-a59f-ef22f01f6cc0_600x600.jpg?v=1732736641\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Swimables","offers":[{"title":"Default Title","offer_id":50599874855203,"sku":"SW-41-054","price":52.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_Igniter_With_Gasket_Kit_For_Pentair_MasterTemp_and_Max-E-Therm_Heaters_77707-0054_SW-41-054_Wholesale_Pool_Mart_1.jpg?v=1738617429"},{"product_id":"pentair-igniter-with-gasket-kit-for-mastertemp-and-max-e-therm-heaters-77707-0054","title":"Pentair Igniter With Gasket Kit For MasterTemp and Max-E-Therm Heaters | 77707-0054","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003eThe OEM Pentair Igniter With Gasket Kit, model 77707-0054, is a crucial component for maintaining the reliable performance of MasterTemp and Max-E-Therm Heaters. This kit includes a high-quality igniter and a gasket, ensuring a secure fit and optimal ignition of your heater. Designed for easy installation, the kit helps restore your heater's functionality, providing quick and efficient ignition. Made from durable materials, both the igniter and gasket in this kit are built to withstand high temperatures and prolonged use, making it an essential part of your heater maintenance and repair toolkit. All MasterTemp heaters are designed with a direct ignition device, HSI (hot-surface ignition), which eliminates the need for a standing pilot. The MasterTemp heater requires an external power source (120\/240 VAC 60 Hz) to operate.\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCrucial Component:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for maintaining the reliable performance of MasterTemp and Max-E-Therm Heaters, ensuring consistent operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-Quality Components:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes a high-quality igniter and gasket, providing a secure fit and optimal ignition of your heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEasy Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for easy installation, allowing you to quickly restore your heater's functionality with efficient ignition.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Materials:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Both the igniter and gasket are made from durable materials, capable of withstanding high temperatures and prolonged use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEfficient Ignition System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e All MasterTemp heaters use a direct ignition device (HSI), eliminating the need for a standing pilot and requiring an external power source (120\/240 VAC 60 Hz).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e Pentair Igniter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair Igniter Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentair Sta-Rite Max-E-Therm Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Igniter_With_Gasket_Kit_For_MasterTemp_and_Max-E-Therm_Heaters_77707-0054_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732736487\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50599878721827,"sku":"77707-0054","price":72.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Igniter_With_Gasket_Kit_For_MasterTemp_and_Max-E-Therm_Heaters_77707-0054_Wholesale_Pool_Mart_1.jpg?v=1738617412"},{"product_id":"pentair-thermal-regulator-kit-for-mastertemp-and-max-e-therm-heaters-77707-0010","title":"Pentair Thermal Regulator Kit For MasterTemp and Max-E-Therm Heaters | 77707-0010","description":"\u003cp\u003eA thermal regulator and an internal bypass regulate the water flow through the heat exchanger to maintain the correct outlet temperature. The heater operator control panel board assembly is located on top of the heater. The thermal regulator kit is specifically crafted for use with Pentair Sta-Rite Max-E-Therm pool and spa heaters, offering compatibility with Pentair MasterTemp pool and spa heaters as well. The kit includes a spring clip and other necessary components. It serves as a reliable thermal regulator replacement kit, fitting seamlessly into Pentair Sta-Rite Max-E-Therm and MasterTemp pool and spa heaters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEfficient Water Flow Regulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The thermal regulator and internal bypass work together to regulate water flow through the heat exchanger, maintaining the correct outlet temperature for optimal performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eControl Panel Integration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The heater operator control panel board assembly is conveniently located on top of the heater, allowing for easy access and operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePrecision Designed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically crafted to fit Pentair Sta-Rite Max-E-Therm pool and spa heaters, ensuring perfect compatibility and seamless integration with MasterTemp models as well.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eComprehensive Kit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes a spring clip and other necessary components for a complete and reliable thermal regulator replacement, ensuring smooth installation and operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhanced Reliability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Serves as a dependable replacement kit, maintaining the efficiency and longevity of your Pentair Sta-Rite Max-E-Therm and MasterTemp pool and spa heaters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair Thermal Regulator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair Thermal Regulator Spring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair Spring Clip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with most Pentair MasterTemp and Max-E-Therm heaters, please refer to your systems owners manual to ensure compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"w-full pt-2 md:pt-0 dark:border-white\/20 md:border-transparent md:dark:border-transparent md:w-[calc(100%-.5rem)]\"\u003e\u003cform class=\"stretch mx-2 flex flex-row gap-3 last:mb-2 md:mx-4 md:last:mb-6 lg:mx-auto lg:max-w-2xl xl:max-w-3xl\"\u003e\n\u003cdiv class=\"relative flex h-full flex-1 flex-col\" style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Thermal_Regulator_Kit_For_MasterTemp_and_Max-E-Therm_Heaters_77707-0010_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732735864\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c\/form\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50599997800739,"sku":"77707-0010","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Thermal_Regulator_Kit_For_MasterTemp_and_Max-E-Therm_Heaters_77707-0010_Wholesale_Pool_Mart_1.jpg?v=1738616892"},{"product_id":"pentair-thermal-regulator-for-mastertemp-and-max-e-therm-heaters-38000-0007s","title":"Pentair Thermal Regulator For MasterTemp and Max-E-Therm Heaters | 38000-0007S","description":"\u003cdiv class=\"description\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Thermal Regulator, complete with a convenient spring clip, offers a versatile and effective solution for pool and spa heater maintenance. This replacement part is specifically designed to fit Pentair Sta-Rite Max-E-Therm pool and spa heaters, ensuring compatibility and seamless integration. Additionally, it is also suitable for use with Pentair MasterTemp pool and spa heaters, providing a versatile option for various heater models. By incorporating this thermal regulator, you can effectively manage and maintain the temperature output of your pool or spa heater, ensuring optimal performance and longevity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eVersatile Solution:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Complete with a convenient spring clip, this thermal regulator offers an effective and versatile solution for pool and spa heater maintenance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePerfect Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically designed to fit Pentair Sta-Rite Max-E-Therm pool and spa heaters, ensuring seamless integration and reliable performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eBroad Usability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Also suitable for use with Pentair MasterTemp pool and spa heaters, providing flexibility for various heater models.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eTemperature Management:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Effectively manages and maintains the temperature output of your pool or spa heater, ensuring consistent and optimal performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhanced Longevity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e By incorporating this thermal regulator, you help extend the lifespan of your heater, maintaining its efficiency and reliability over time.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eThermal Regulator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003eSpring Clip\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with most Pentair MasterTemp and Max-E-Therm heaters, please refer to your systems owners manual to ensure compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"highlights\" style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Thermal_Regulator_For_MasterTemp_and_Max-E-Therm_Heaters_38000-0007S_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732735937\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600007696675,"sku":"38000-0007S","price":62.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Thermal_Regulator_For_MasterTemp_and_Max-E-Therm_Heaters_38000-0007S_Wholesale_Pool_Mart_1.jpg?v=1738616867"},{"product_id":"swimables-water-pressure-switch-for-pentair-mastertemp-and-max-e-therm-heaters-42001-0060s-sw-41-060","title":"Swimables Water Pressure Switch For Pentair MasterTemp and Max-E-Therm Heaters | 42001-0060S | SW-41-060","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe Swimables Pentair Water Pressure Switch, model SW-41-060, is designed for use with MasterTemp and Max-E-Therm heaters. This essential component monitors and maintains the correct water pressure within the heating system, ensuring safe and efficient operation. Constructed from reliable, high-quality materials, the pressure switch offers durability and long-term performance. It’s a critical part for preventing overheating and protecting the heater from damage, thus extending the lifespan and maintaining the efficiency of your pool or spa heating system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eSpecifically Designed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Tailored for use with MasterTemp and Max-E-Therm heaters, ensuring compatibility and optimal performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCritical Pressure Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monitors and maintains the correct water pressure within the heating system, ensuring safe and efficient operation to prevent system failures.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Crafted from reliable, high-quality materials for long-term performance and resilience, even under continuous use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePrevents Overheating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A vital component in preventing overheating and protecting the heater from potential damage, thus extending the heater's lifespan.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances System Efficiency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Contributes to the overall efficiency of your pool or spa heating system by maintaining optimal pressure levels and ensuring smooth operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1)\u003c\/strong\u003e Swimables SW-41-060 Water Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentai Max-E-Therm Heaters\u003c\/li\u003e\n\u003cli\u003ePentair ETI 400 Heaters\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_Water_Pressure_Switch_For_Pentair_MasterTemp_and_Max-E-Therm_Heaters_42001-0060S_SW-41-060_Wholesale_Pool_Mart_diagram_35bb343a-8ebb-432e-9c87-123a9282fd15_600x600.jpg?v=1732735681\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Swimables","offers":[{"title":"Default Title","offer_id":50600017789219,"sku":"SW-41-060","price":46.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Swimables_Water_Pressure_Switch_For_Pentair_MasterTemp_and_Max-E-Therm_Heaters_42001-0060S_SW-41-060_Wholesale_Pool_Mart_1.jpg?v=1738616831"},{"product_id":"pentair-water-pressure-switch-for-mastertemp-and-max-e-therm-heaters-42001-0060s","title":"Pentair Water Pressure Switch For MasterTemp and Max-E-Therm Heaters | 42001-0060S","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe Pentair Water Pressure Switch, model 42001-0060S, is designed for use with MasterTemp and Max-E-Therm heaters. This essential component monitors and maintains the correct water pressure within the heating system, ensuring safe and efficient operation. Constructed from reliable, high-quality materials, the pressure switch offers durability and long-term performance. It’s a critical part for preventing overheating and protecting the heater from damage, thus extending the lifespan and maintaining the efficiency of your pool or spa heating system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eSpecifically Designed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Tailored for use with MasterTemp and Max-E-Therm heaters, ensuring compatibility and optimal performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCritical Pressure Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Monitors and maintains the correct water pressure within the heating system, ensuring safe and efficient operation to prevent system failures.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Crafted from reliable, high-quality materials for long-term performance and resilience, even under continuous use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePrevents Overheating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A vital component in preventing overheating and protecting the heater from potential damage, thus extending the heater's lifespan.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances System Efficiency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Contributes to the overall efficiency of your pool or spa heating system by maintaining optimal pressure levels and ensuring smooth operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair 42001-0060S Water Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentai Max-E-Therm Heaters\u003c\/li\u003e\n\u003cli\u003ePentair ETI 400 Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Water_Pressure_Switch_For_MasterTemp_and_Max-E-Therm_Heaters_42001-0060S_Wholesale_Pool_Mart_diagram_f97c6b7d-e6a9-45d0-b5c0-2ec3b21863b1_600x600.jpg?v=1732735633\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600022999331,"sku":"42001-0060S","price":70.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Water_Pressure_Switch_For_MasterTemp_and_Max-E-Therm_Heaters_42001-0060S_Wholesale_Pool_Mart_1.jpg?v=1738616818"},{"product_id":"pentair-manifold-bypass-valve-for-mastertemp-and-max-e-therm-heaters-77707-0001","title":"Pentair Manifold Bypass Valve For MasterTemp and Max-E-Therm Heaters | 77707-0001","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eThe Pentair Manifold Bypass Valve, model 77707-0001, is designed specifically for use with MasterTemp and Max-E-Therm heaters. This component plays a crucial role in regulating water flow, ensuring optimal heater performance and efficiency by diverting water flow as necessary. Made from high-quality, durable materials, the bypass valve is built to withstand the demands of frequent use and harsh pool environments. It’s an essential part for maintaining reliable operation and extending the life of your Pentair heater.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eTailored Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically designed for use with MasterTemp and Max-E-Therm heaters, ensuring perfect fit and seamless integration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCrucial Water Flow Regulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Plays a vital role in regulating water flow, essential for maintaining optimal heater performance and efficiency by diverting water as needed.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built from high-quality, durable materials, this valve withstands frequent use and harsh pool environments, ensuring longevity and reliability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEnhances Heater Longevity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Integral to maintaining reliable operation and extending the lifespan of your Pentair heater, thereby protecting your investment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eOptimized Performance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ensures your heater operates at peak performance, reducing wear and tear and improving the overall efficiency of your pool heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e(1) \u003c\/strong\u003ePentair 77707-0001 Manifold Bypass Valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\" dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003ePentair MasterTemp Heaters\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\" dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003ePentair Sta-Rite Max-E-Therm Heater\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Manifold_Bypass_Valve_For_MasterTemp_and_Max-E-Therm_Heaters_77707-0001_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732735425\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600034894115,"sku":"77707-0001","price":51.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Manifold_Bypass_Valve_For_MasterTemp_and_Max-E-Therm_Heaters_77707-0001_Wholesale_Pool_Mart_1.jpg?v=1738616773"},{"product_id":"raypak-pc-control-board-kit-for-raypak-heaters-3-wire-100-10000345","title":"Raypak 100-10000345 3 Wire PC Control Board Kit | 206A-408A Heaters","description":"\u003cp data-start=\"344\" data-end=\"1190\"\u003eThe Raypak 100-10000345 PC Control Board Kit is the primary electronic controller used in Raypak digital gas pool and spa heaters, replacing the earlier 013464F board while maintaining full original functionality. Built to Raypak OEM specifications, this three-wire control board manages ignition sequencing, 24-volt power distribution, flame sensing, diagnostics, and overall heater logic for models 206A, 266A, 336A, 406A, and 408A manufactured from the mid-2000s onward. An integrated LCD display provides clear plain-text diagnostic messages and improved flame signal feedback, helping simplify troubleshooting and ongoing maintenance. Supplied as a complete kit with the required wiring harness components, this board restores dependable heater operation and consistent performance when the original control begins to fail.\u003c\/p\u003e\n\u003ch3 data-start=\"1192\" data-end=\"1210\"\u003e\u003cstrong data-start=\"1196\" data-end=\"1210\"\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1211\" data-end=\"2021\"\u003e\n\u003cli data-start=\"1211\" data-end=\"1389\"\u003e\n\u003cp data-start=\"1213\" data-end=\"1389\"\u003e\u003cstrong data-start=\"1213\" data-end=\"1253\"\u003eDesigned for Raypak Digital Heaters:\u003c\/strong\u003e Matches the factory control board used on Raypak 206A, 266A, 336A, 406A, and 408A heater models for proper integration and operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1390\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1392\" data-end=\"1551\"\u003e\u003cstrong data-start=\"1392\" data-end=\"1428\"\u003eThree Wire Control Architecture:\u003c\/strong\u003e Regulates power delivery, ignition timing, flame sensing, and heater sequencing using a stable three-wire configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1552\" data-end=\"1707\"\u003e\n\u003cp data-start=\"1554\" data-end=\"1707\"\u003e\u003cstrong data-start=\"1554\" data-end=\"1588\"\u003ePlain Text Diagnostic Display:\u003c\/strong\u003e LCD screen provides readable diagnostic messages and system feedback to streamline troubleshooting and service work.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1708\" data-end=\"1858\"\u003e\n\u003cp data-start=\"1710\" data-end=\"1858\"\u003e\u003cstrong data-start=\"1710\" data-end=\"1747\"\u003eImproved Flame Signal Processing:\u003c\/strong\u003e Updated sensing logic enhances ignition accuracy and helps reduce nuisance shutdowns or misdiagnosed faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1859\" data-end=\"2021\"\u003e\n\u003cp data-start=\"1861\" data-end=\"2021\"\u003e\u003cstrong data-start=\"1861\" data-end=\"1890\"\u003eComplete Replacement Kit:\u003c\/strong\u003e Includes the PC board and required harness components to support straightforward installation during repairs or system upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaypak Heater Models: \u003c\/strong\u003e206A, 266A, 336A, 406A, 207A, 267A, 337A, 407A, 268, 408\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cb id=\"docs-internal-guid-4031eeae-7fff-5d67-1c8f-bb390aa406e8\"\u003e\u003cspan\u003eNote: \u003c\/span\u003e\u003c\/b\u003eThis control board may be compatible with your heater, please check owners manual to ensure compatibility.\u003c\/p\u003e\n\u003ch3 data-start=\"2867\" data-end=\"2886\"\u003eAdditional Info\u003c\/h3\u003e\n\u003cp data-start=\"2887\" data-end=\"3251\"\u003eThe Raypak 100-10000345 PC Control Board Kit restores digital control and diagnostics in compatible Raypak gas heaters. This section supports Wholesale Pool Mart customers, including local service professionals, by covering compatibility checks, failure patterns, and installation planning. These FAQs focus on minimizing downtime and improving service efficiency.\u003c\/p\u003e\n\u003ch2 data-start=\"3253\" data-end=\"3295\"\u003eCompatibility and System Verification\u003c\/h2\u003e\n\u003cp data-start=\"3296\" data-end=\"3378\"\u003eService professionals often confirm board compatibility before scheduling repairs.\u003c\/p\u003e\n\u003ch4 data-start=\"3380\" data-end=\"3456\"\u003eIs the 100-10000345 board compatible with Raypak 266A and 336A heaters?\u003c\/h4\u003e\n\u003cp data-start=\"3457\" data-end=\"3576\"\u003eYes, it supports Raypak 206A, 266A, 336A, 406A, and 408A digital heater models that use the 3-wire controller platform.\u003c\/p\u003e\n\u003ch4 data-start=\"3578\" data-end=\"3652\"\u003eCan this board replace a failing 013464F without rewiring the heater?\u003c\/h4\u003e\n\u003cp data-start=\"3653\" data-end=\"3755\"\u003eYes, it is designed as a direct replacement and integrates with existing heater wiring and components.\u003c\/p\u003e\n\u003ch4 data-start=\"3757\" data-end=\"3826\"\u003eWill installing this board resolve intermittent ignition faults?\u003c\/h4\u003e\n\u003cp data-start=\"3827\" data-end=\"3932\"\u003eIn many cases, yes. Control boards that misread flame signals often cause inconsistent ignition behavior.\u003c\/p\u003e\n\u003ch2 data-start=\"3934\" data-end=\"3973\"\u003eInstallation and Field Diagnostics\u003c\/h2\u003e\n\u003cp data-start=\"3974\" data-end=\"4023\"\u003eThese FAQs address real-world service conditions.\u003c\/p\u003e\n\u003ch4 data-start=\"4025\" data-end=\"4086\"\u003eWhy does Raypak recommend upgrading to this newer board?\u003c\/h4\u003e\n\u003cp data-start=\"4087\" data-end=\"4206\"\u003eThe updated board provides improved flame-sensing feedback and clearer diagnostics, reducing misdiagnosis in the field.\u003c\/p\u003e\n\u003ch4 data-start=\"4208\" data-end=\"4259\"\u003eDoes the LCD display speed up troubleshooting?\u003c\/h4\u003e\n\u003cp data-start=\"4260\" data-end=\"4364\"\u003eYes, technicians can quickly identify fault conditions using plain-text messages instead of error codes.\u003c\/p\u003e\n\u003ch4 data-start=\"4366\" data-end=\"4435\"\u003eHow long does replacement typically take during a service visit?\u003c\/h4\u003e\n\u003cp data-start=\"4436\" data-end=\"4561\"\u003eInstallation is usually straightforward and can be completed efficiently when connectors and harnesses are in good condition.\u003c\/p\u003e\n\u003ch2 data-start=\"4563\" data-end=\"4606\"\u003eLocal Pricing and Service Coordination\u003c\/h2\u003e\n\u003cp data-start=\"4607\" data-end=\"4678\"\u003eWholesale Pool Mart customers often plan parts ahead of service routes.\u003c\/p\u003e\n\u003ch4 data-start=\"4680\" data-end=\"4751\"\u003eCan technicians check nearby shop stock before scheduling repairs?\u003c\/h4\u003e\n\u003cp data-start=\"4752\" data-end=\"4848\"\u003eYes, checking nearby shop stock helps coordinate faster heater repairs and reduce return visits.\u003c\/p\u003e\n\u003ch4 data-start=\"4850\" data-end=\"4908\"\u003eDo service teams commonly carry this board on trucks?\u003c\/h4\u003e\n\u003cp data-start=\"4909\" data-end=\"4995\"\u003eYes, control board failures are common, making this a frequently stocked service part.\u003c\/p\u003e\n\u003ch4 data-start=\"4997\" data-end=\"5054\"\u003eAre other components often serviced with this board?\u003c\/h4\u003e\n\u003cp data-start=\"5055\" data-end=\"5156\"\u003eIgniters, flame sensors, and pressure switches are commonly checked during control board replacement.\u003c\/p\u003e\n\u003ch3\u003eDiagram\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_PC_Control_Board_Kit_For_Raypak_Heaters_3_Wire_100-10000345_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732747908\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003c!----\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50600461140259,"sku":"100-10000345","price":269.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Raypak_PC_Control_Board_Kit_For_Raypak_Heaters_3_Wire_100-10000345_Wholesale_Pool_Mart_1.jpg?v=1738615222"},{"product_id":"pentair-thermistor-for-mastertemp-sta-rite-max-e-therm-eti-400-gas-heaters-42001-0053s","title":"Pentair Thermistor for MasterTemp Sta-Rite Max-E-Therm ETI 400 Gas Heaters | 42001-0053S","description":"\u003cp\u003e\u003cspan\u003eThe OEM Pentair Thermistor 42001-0053S is responsible for displaying the temperature on your control panel. Typically if the display reading is indicating a temperature that is too high then your thermistor needs to replaced. \u003c\/span\u003e\u003cspan\u003eThe Thermistor cannot be reset, it must be replaced. This OEM Pentair Thermistor 42001-0053S is compatible with most Pentair MasterTemp, Sta-Rite Max-E-Therm and ETI 400 Natural Gas Swimming Pool Heaters. An electronic temperature sensing thermistor in the manifold adapter inlet controls the heater operation. When the inlet water temperature drops below the temperature set on the operating control, the burner controller supplies power to the combustion air blower through a series of safety interlocks\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCrucial Temperature Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Vital for accurately reflecting the water temperature on control panels, signaling when a replacement is needed for consistent monitoring.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eNon-Resettable OEM Part:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This Original Equipment Manufacturer (OEM) thermistor guarantees a precise fit and function for specified Pentair heaters, necessitating replacement, not resetting, when faulty.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eWide Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to integrate seamlessly with most Pentair MasterTemp, Sta-Rite Max-E-Therm, and ETI 400 Natural Gas Pool Heaters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eIntelligent Heating Control:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically regulates the heater operation through an electronic temperature-sensing mechanism, ensuring safety and efficiency.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair Sta-Rite Max-E-Therm Heaters\u003c\/li\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentair ETI 400 Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Thermistor_for_MasterTemp_Sta-Rite_Max-E-Therm_ETI_400_Gas_Heaters_42001-0053S_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732725709\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600697856291,"sku":"42001-0053S","price":71.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Thermistor_for_MasterTemp_Sta-Rite_Max-E-Therm_ETI_400_Gas_Heaters_42001-0053S_Wholesale_Pool_Mart_1.jpg?v=1738614189"},{"product_id":"pentair-high-limit-switch-for-mastertemp-and-max-e-therm-heaters-42001-0063s","title":"Pentair High Limit Switch for MasterTemp And Max-E-Therm Heaters | 42001-0063S","description":"\u003cp\u003e\u003cspan\u003eThe OEM Pentair Hi Limit Switch 42001-0063S is a safety switch used to detect when water temperature has exceeded a safe level (135°F) and immediately opens the heat exchanger out. When this fails, your system will typically show error code HLS. \u003c\/span\u003e\u003cspan\u003eThe Hi Limit Switch cannot be reset, it must be replaced. This OEM Pentair Hi Limit Switch 42001-0063SS is compatible with most Pentair MasterTemp and Sta-Rite Max-E-Therm Natural Gas Swimming Pool Heaters. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eCritical Safety Feature:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Activates by detecting unsafe water temperatures above 135°F, instantly preventing heat exchanger overload.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eError Code Indicator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to display an HLS error code as a clear indicator of failure, necessitating a timely replacement.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eMandatory Replacement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e As a non-resettable component, this OEM Hi Limit Switch is built to be replaced, not repaired, ensuring ongoing safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eBroad Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible with a wide range of Pentair heaters, including MasterTemp and Sta-Rite Max-E-Therm Natural Gas models.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePentair Sta-Rite Max-E-Therm Heaters\u003c\/li\u003e\n\u003cli\u003ePentair MasterTemp Heaters\u003c\/li\u003e\n\u003cli\u003ePentair ETI 400 Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_High_Limit_Switch_for_MasterTemp_And_Max-E-Therm_Heaters_42001-0063S_Wholesale_Pool_Mart_diagram_8b1877f8-59b5-408f-acdb-5949ea0f4f81_600x600.jpg?v=1732725592\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600699363619,"sku":"42001-0063S","price":52.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_High_Limit_Switch_for_MasterTemp_And_Max-E-Therm_Heaters_42001-0063S_Wholesale_Pool_Mart_1.jpg?v=1738614176"},{"product_id":"pentair-control-board-eti-400-gas-pool-heater-475975","title":"Pentair Control Board ETI 400 Gas Pool Heater | 475975","description":"\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eDesigned for seamless integration and reliable performance, the OEM Pentair Control Board 475975 acts as the central hub of operations for the Pentair ETI 400 Gas Heater Model 461113. It meticulously orchestrates the function of the combustion air blowers, managing the safety interlocks to ensure proper operation and safety. Built to OEM specifications, it not only restores functionality but also upholds the manufacturer's standards, making it the preferable choice for both maintenance and repair tasks. This control board's role is pivotal for heater longevity and efficiency, making it a wise investment for uninterrupted pool enjoyment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eSeamless Integration:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Engineered as the central hub for the Pentair ETI 400 Gas Heater Model 461113, ensuring flawless performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eManaged Operations:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Controls and coordinates the combustion air blowers and safety interlocks, providing exceptional reliability and safety.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eOEM Standards:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Constructed to original manufacturer specifications to restore and maintain the heater's proper function at peak standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eVital for Long-Term Efficiency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for the long-term efficiency and longevity of the heater, representing a smart investment for sustained pool enjoyment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with Pentair ETI 400 Pool Heaters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Control_Board_ETI_400_Gas_Pool_Heater_475975_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732725775\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600703983907,"sku":"475975","price":129.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Control_Board_ETI_400_Gas_Pool_Heater_475975_Wholesale_Pool_Mart_2.jpg?v=1738614148"},{"product_id":"pentair-ignition-control-module-for-eti-400-heater-475976","title":"Pentair Ignition Control Module For ETi 400 Heater | 475976","description":"\u003cdiv class=\"styled__MarkdownFormatting-sc-e1a37c03-1 hLMZXo mt-1 text-sm text-textcolor-900\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cspan\u003eEnsure a seamless start to your pool heating with the Pentair Ignition Control Module, designed specifically for the ETi 400 Heater, part number 475976. This critical component reliably manages the ignition process, supervising the electrical sequences that start the heater and consistently monitoring to maintain safe operation. The module is built to meet the rigorous standards of Pentair, offering a high degree of durability and resilience against the elements. With straightforward installation, it's a key investment for the longevity and efficiency of your ETi 400 Heater, keeping your pool's temperature perfectly regulated for comfortable swimming throughout the seasons.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"my-4 break-words text-sm first:mt-0 only:my-0\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"my-2 ml-6 list-disc text-sm\"\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eSeamless Ignition Management:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ensures a flawless start by expertly handling the ignition sequences of the ETi 400 Heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous Safety Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Offers peace of mind with constant supervision to maintain the heater's safe operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003ePentair Durability Standards:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Meets Pentair's strict quality criteria, ensuring resilience and long-term performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"my-2\"\u003e\n\u003cstrong\u003e\u003cspan\u003eEffortless Installation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for simplicity, facilitating a hassle-free setup that complements the ETi 400 Heater's efficiency.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600823390499,"sku":"475976","price":189.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/PentairIgnitionControlModuleForETi400Heater475976WholesalePoolMart2.jpg?v=1738613039"},{"product_id":"jandy-gas-valve-for-jxi-heaters-r0591400","title":"Jandy R0591400 Gas Valve | For JXi Heaters","description":"\u003cp data-start=\"1625\" data-end=\"2167\" class=\"\"\u003eOEM Jandy Gas Valve R0591400 is specifically crafted to regulate gas flow in Jandy JXI Heaters, ensuring stable operation and dependable heat output. This valve plays a vital role in maintaining your heater’s safety and performance by controlling the supply of gas with high accuracy. Built for long-term durability, it offers a secure, direct fit for JXI units and installs with ease. Whether replacing a malfunctioning valve or performing preventative maintenance, this component helps ensure your pool heater continues running at its best.\u003c\/p\u003e\n\u003ch3 data-start=\"2169\" data-end=\"2183\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2184\" data-end=\"2787\"\u003e\n\u003cli data-start=\"2184\" data-end=\"2301\" class=\"\"\u003e\n\u003cp data-start=\"2186\" data-end=\"2301\" class=\"\"\u003e\u003cstrong data-start=\"2186\" data-end=\"2216\"\u003ePrecision Fuel Regulation:\u003c\/strong\u003e Designed to deliver exact gas flow to maintain efficient and safe burner operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2302\" data-end=\"2422\" class=\"\"\u003e\n\u003cp data-start=\"2304\" data-end=\"2422\" class=\"\"\u003e\u003cstrong data-start=\"2304\" data-end=\"2329\"\u003eMade for JXI Heaters:\u003c\/strong\u003e Compatible with Jandy JXI models to guarantee proper fit and optimal heating functionality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2423\" data-end=\"2541\" class=\"\"\u003e\n\u003cp data-start=\"2425\" data-end=\"2541\" class=\"\"\u003e\u003cstrong data-start=\"2425\" data-end=\"2456\"\u003eReliable and Durable Build:\u003c\/strong\u003e Manufactured from strong, heat-resistant materials to handle frequent heater usage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2542\" data-end=\"2663\" class=\"\"\u003e\n\u003cp data-start=\"2544\" data-end=\"2663\" class=\"\"\u003e\u003cstrong data-start=\"2544\" data-end=\"2575\"\u003eEnsures Operational Safety:\u003c\/strong\u003e Plays a critical role in safe system performance by regulating fuel input effectively\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2664\" data-end=\"2787\" class=\"\"\u003e\n\u003cp data-start=\"2666\" data-end=\"2787\" class=\"\"\u003e\u003cstrong data-start=\"2666\" data-end=\"2699\"\u003eQuick and Secure Replacement:\u003c\/strong\u003e Installs with minimal effort, helping restore heater performance quickly and reliably\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFits Jandy JXI400N, JXI400NK, JXI400NN, JXI260N, JXI260NK, JXI200N, JXI200NK, JXI400NC, JXI260NC Natural and JXI400P, JXI400PN, JXI400PK, JXI260P, JXI260PK, JXI200P, JXI200PK, JXI400PC, JXI260PC Propane Heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis gas valve may be compatible with your heater, please check owners manual to ensure compatibility\u003c\/p\u003e\n\u003ch3 data-start=\"1517\" data-end=\"1536\" class=\"\"\u003eAdditional Info\u003c\/h3\u003e\n\u003ch2 data-start=\"1538\" data-end=\"1590\" class=\"\"\u003eR0591400 Gas Valve For Local JXI Heater Repairs\u003c\/h2\u003e\n\u003ch4 data-start=\"1591\" data-end=\"1659\" class=\"\"\u003efits JXI400NK, JXI260NC, JXI200P, and other compatible models\u003c\/h4\u003e\n\u003ch4 data-start=\"1660\" data-end=\"1733\" class=\"\"\u003eavailable locally – restores proper gas regulation in pool heaters\u003c\/h4\u003e\n\u003ch4 data-start=\"1734\" data-end=\"1800\" class=\"\"\u003eused by local techs for heater startup and fuel flow issues\u003c\/h4\u003e\n\u003ch4 data-start=\"1801\" data-end=\"1864\" class=\"\"\u003eR0591400 includes OEM spec valve for safe gas management\u003c\/h4\u003e\n\u003ch4 data-start=\"1865\" data-end=\"1921\" class=\"\"\u003ehelps fix inconsistent heating and startup delays\u003c\/h4\u003e\n\u003ch2 data-start=\"1923\" data-end=\"1989\" class=\"\"\u003eLocal Pickup – R0591400 Valve For JXI Natural \u0026amp; Propane Units\u003c\/h2\u003e\n\u003ch4 data-start=\"1990\" data-end=\"2060\" class=\"\"\u003epart R0591400 used in propane and natural gas JXI installations\u003c\/h4\u003e\n\u003ch4 data-start=\"2061\" data-end=\"2127\" class=\"\"\u003econtrols fuel delivery for Jandy JXI400, JXI200, and JXI260\u003c\/h4\u003e\n\u003ch4 data-start=\"2128\" data-end=\"2189\" class=\"\"\u003epick up R0591400 locally for urgent service or repairs\u003c\/h4\u003e\n\u003ch4 data-start=\"2190\" data-end=\"2250\" class=\"\"\u003eessential part for restoring gas pressure consistency\u003c\/h4\u003e\n\u003ch4 data-start=\"2251\" data-end=\"2305\" class=\"\"\u003eused in local heater rebuilds and burner tuning\u003c\/h4\u003e\n\u003ch2 data-start=\"2307\" data-end=\"2361\" class=\"\"\u003eJandy R0591400 For Gas Line Repair On JXI Heaters\u003c\/h2\u003e\n\u003ch4 data-start=\"2362\" data-end=\"2429\" class=\"\"\u003ereplaces failed gas valve in 200K, 260K, and 400K BTU models\u003c\/h4\u003e\n\u003ch4 data-start=\"2430\" data-end=\"2505\" class=\"\"\u003efits JXI series pool heaters for both residential and commercial use\u003c\/h4\u003e\n\u003ch4 data-start=\"2506\" data-end=\"2575\" class=\"\"\u003elocal availability for fuel flow fixes in Jandy heater systems\u003c\/h4\u003e\n\u003ch4 data-start=\"2576\" data-end=\"2645\" class=\"\"\u003einstalls in control section of JXI unit with existing hardware\u003c\/h4\u003e\n\u003ch4 data-start=\"2646\" data-end=\"2713\" class=\"\"\u003epart used during full heater diagnostic and rebuild services\u003c\/h4\u003e\n\u003ch3\u003eDiagram\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Gas_Valve_For_JXI_Heaters_R0591400_Wholesale_Pool_Mart_Diagram_600x600.jpg?v=1732899507\"\u003e\u003c\/div\u003e","brand":"Jandy","offers":[{"title":"Default Title","offer_id":50600853831971,"sku":"R0591400","price":359.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Jandy_Gas_Valve_For_JXI_Heaters_R0591400_Wholesale_Pool_Mart_1.jpg?v=1738612732"},{"product_id":"hayward-h-series-heater-integrated-control-board-replacement-kit-fdxlicb1930","title":"Hayward FDXLICB1930 Integrated Control Board | For H-Series","description":"\u003cp data-start=\"1874\" data-end=\"2484\" class=\"\"\u003eOEM Hayward FDXLICB1930 Integrated Control Board Kit is a critical replacement part for H-Series Low NOx pool heaters, supporting reliable operation in units made after September 20, 2004. This board controls the core electrical functions of the heater, including safety systems and ignition, ensuring smooth performance and consistent heat delivery. Manufactured to Hayward’s strict standards, the FDXLICB1930 is essential for resolving system faults and maintaining peak energy efficiency. Designed for easy installation, it plays a key role in reducing service interruptions and preserving heater life span.\u003c\/p\u003e\n\u003ch3 data-start=\"2486\" data-end=\"2502\" class=\"\"\u003eHighlights\u003c\/h3\u003e\n\u003cul data-start=\"2503\" data-end=\"3185\"\u003e\n\u003cli data-start=\"2503\" data-end=\"2635\" class=\"\"\u003e\n\u003cp data-start=\"2505\" data-end=\"2635\" class=\"\"\u003e\u003cstrong data-start=\"2505\" data-end=\"2537\"\u003eDirect OEM Replacement Part:\u003c\/strong\u003e Genuine Hayward control board designed to support high-performance Low NOx pool and spa heaters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2636\" data-end=\"2783\" class=\"\"\u003e\n\u003cp data-start=\"2638\" data-end=\"2783\" class=\"\"\u003e\u003cstrong data-start=\"2638\" data-end=\"2672\"\u003eFits Post-2004 H-Series Units:\u003c\/strong\u003e Compatible with a wide range of models manufactured after September 20, 2004, ensuring accurate system match\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2784\" data-end=\"2923\" class=\"\"\u003e\n\u003cp data-start=\"2786\" data-end=\"2923\" class=\"\"\u003e\u003cstrong data-start=\"2786\" data-end=\"2821\"\u003eControls Core System Functions:\u003c\/strong\u003e Governs ignition, diagnostics, and operational safety features to maintain dependable heater cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2924\" data-end=\"3051\" class=\"\"\u003e\n\u003cp data-start=\"2926\" data-end=\"3051\" class=\"\"\u003e\u003cstrong data-start=\"2926\" data-end=\"2954\"\u003eFast, Hassle-Free Setup:\u003c\/strong\u003e Built with plug-and-play functionality to simplify field replacement during service or repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3052\" data-end=\"3185\" class=\"\"\u003e\n\u003cp data-start=\"3054\" data-end=\"3185\" class=\"\"\u003e\u003cstrong data-start=\"3054\" data-end=\"3100\"\u003eImproves Heater Longevity and Performance:\u003c\/strong\u003e Maintains manufacturer-rated energy efficiency and system responsiveness over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHayward H-Series Heaters Models:\u003c\/span\u003e\u003c\/strong\u003e H150FDN, H150FDP, H200FDN, H200FDP, H250FDN, H250FDP, H300FDN, H300FDP, H350FDN, H350FDP, H400FDN, H400FDP, H500FD\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagram\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_H-Series_Heater_Integrated_Control_Board_Replacement_Kit_FDXLICB1930_Wholesale_Pool_Mart_diagram_600x600.jpg?v=1732744716\" alt=\"\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Hayward","offers":[{"title":"Default Title","offer_id":50600872378659,"sku":"FDXLICB1930","price":379.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Hayward_H-Series_Heater_Integrated_Control_Board_Replacement_Kit_FDXLICB1930_Wholesale_Pool_Mart_1.jpg?v=1736789018"},{"product_id":"pentair-control-board-with-6-button-pad-for-mastertemp-and-max-e-therm-heaters-42002-0007s-461105","title":"Pentair Control Board with 6 Button Pad For MasterTemp and Max-E-Therm Heaters | 42002-0007S | 461105","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe OEM Pentair part 461105, formerly 42002-0007S, is a vital component for optimizing your Pentair MasterTemp or Sta-Rite Max-E-Therm pool heater. This control board kit includes everything needed for efficient operation and precise temperature control. Compatible with both heater models, it features a membrane pad with six buttons for easy settings adjustment and RS-485 connectivity for seamless integration into your pool automation system. With straightforward installation instructions included, this kit ensures hassle-free setup, whether you're replacing a worn-out board or upgrading for enhanced functionality. Trust Pentair for top-quality components, keeping your pool or spa running smoothly year-round.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb data-mce-fragment=\"1\"\u003eEfficient Temperature Control:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e The control board kit ensures precise temperature regulation for your pool or spa, optimizing the performance of your Pentair MasterTemp or Sta-Rite Max-E-Therm heater.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-mce-fragment=\"1\"\u003eSeamless Integration:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e With RS-485 connectivity, this kit seamlessly integrates into your pool automation system, enhancing overall functionality and control.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb data-mce-fragment=\"1\"\u003eStraightforward Installation:\u003c\/b\u003e\u003cspan style=\"font-weight: 400;\" data-mce-fragment=\"1\"\u003e Equipped with clear installation instructions, the kit simplifies setup, whether you're replacing an old board or upgrading for enhanced performance, ensuring a hassle-free experience.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eControl Board Kit for the following Heaters:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePentair MasterTemp\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSta-Rite Max-E-Therm\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e*Formerly known as 42002-0007S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFor use with both Natural Gas and Propane heaters. Pentair OEM Product. Control PCB\/Membrane Pad Replacement.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eIncludes\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\" data-mce-fragment=\"1\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003e(1)\u003c\/strong\u003e MEM Pad MT 6 Buttons - \u003cstrong\u003e476201\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003e(1)\u003c\/strong\u003e PCBA MT\/MET Heater with RS-485 - \u003cstrong\u003e476199 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003e(1) \u003c\/strong\u003e Installation Instructions - \u003cstrong\u003e476248\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/Pentair_Control_Board_with_6_Button_Pad_For_MasterTemp_and_Max-E-Therm_Heaters_42002-0007S_461105_Wholesale_Pool_Mart_diagram_558e4601-74bb-46e4-b88a-8bf151cb8be8_600x600.jpg?v=1732736361\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":50600942174499,"sku":"461105","price":498.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/PentairControlBoardwith6ButtonPadForMasterTempandMax-E-ThermHeaters42002-0007S461105WholesalePoolMART_3.jpg?v=1783723405"},{"product_id":"raypak-hot-surface-ignitor-for-hsi-high-delta-heaters-007400f","title":"Raypak Hot Surface Ignitor For HSI High Delta Heaters | 007400F","description":"\u003cp data-start=\"0\" data-end=\"164\"\u003e​\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eThe Raypak Hot Surface Ignitor 007400F is a genuine OEM replacement component designed for use with Raypak Hi Delta 992-2342 heaters.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eEngineered to meet original equipment specifications, this ignitor ensures reliable ignition performance and compatibility with your heating system.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eIts durable construction and precise design contribute to the efficient operation of your heater, maintaining optimal performance and safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"0\" data-end=\"164\"\u003e\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"0\" data-end=\"110\"\u003e\n\u003cstrong data-start=\"2\" data-end=\"22\" data-is-only-node=\"\"\u003eOEM Replacement:\u003c\/strong\u003e Specifically designed for Raypak Hi Delta 992-2342 heaters for perfect compatibility.\u003c\/li\u003e\n\u003cli data-start=\"111\" data-end=\"216\"\u003e\n\u003cstrong data-start=\"113\" data-end=\"135\" data-is-only-node=\"\"\u003eReliable Ignition:\u003c\/strong\u003e Ensures consistent and efficient ignition performance for your heating system.\u003c\/li\u003e\n\u003cli data-start=\"217\" data-end=\"327\"\u003e\n\u003cstrong data-start=\"219\" data-end=\"245\" data-is-only-node=\"\"\u003ePrecision Engineering:\u003c\/strong\u003e Manufactured to original equipment specifications for optimal fit and function.\u003c\/li\u003e\n\u003cli data-start=\"328\" data-end=\"421\"\u003e\n\u003cstrong data-start=\"330\" data-end=\"355\" data-is-only-node=\"\"\u003eDurable Construction:\u003c\/strong\u003e Built to withstand high-temperature conditions and regular use.\u003c\/li\u003e\n\u003cli data-start=\"422\" data-end=\"541\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"424\" data-end=\"458\" data-is-only-node=\"\"\u003eMaintains Efficiency \u0026amp; Safety:\u003c\/strong\u003e Supports proper heater operation while upholding safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"0\" data-end=\"164\"\u003e\u003cstrong\u003eCompatibility​\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem]\"\u003eRaypak HSI High Delta Heater Models: \u003c\/span\u003e\u003c\/strong\u003e992, 1262, 1532, 1802, 2002, 2072, 2342\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagram\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":53486396604707,"sku":"007400F","price":59.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/0987\/5235\/files\/RaypakHotSurfaceIgnitorForHSIHighDeltaHeaters007400F_1.png?v=1743524336"}],"url":"https:\/\/wholesalepoolmart.com\/collections\/fix-heater-not-working.oembed?page=2","provider":"Wholesale Pool Mart","version":"1.0","type":"link"}